To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 205 of 5258

Allow configurable PI Point Lookup priority whether to use PI Point name or PI Point ID first

Currently, in PI Vision display, PI Points data items are stored using both the PI Point ID and PI Point Name. During data retrieval, PI Vision prioritizes resolution via PI Point ID and only falls back to PI Point Name if the PI Point ID is not f...
Mohammed Al-Shaikh 5 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 5 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 11 months ago in AVEVA™ Adapters / General 0 No status

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 3 months ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Export data from the Display Sessions to a PI Point through an interface or performance counter

The Display sessions are very useful for daily monitoring. But having the option that allows us to save the data from this utility to a PI Point or attribute for later analysis would be useful for monitoring purposes
Guest 10 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Add ability to report on the displays shared with a specific identity

As a PI Vision Admin, I'd like to be able to report on the displays shared with a specific identity.
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 2 No status

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 4 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status