To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 41 of 5192

Option to disable automatic connections to AF Servers

I would like the ability to disable automatic connections to specific AF Servers. Currently client applications (DataLink) are implicitly connecting to all AF Servers in the AF "KST". This results in very slow startup times for Excel. For customer...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 0 No status

Add a new diagnostic: the IO rate in bytes or megabytes

The current IO rate diagnostic is helpful, but it only shows events per second. For sites who need to manage their bandwidth and make decisions about how much to buy and support from remote sites, it's very important to be able to monitor exactly ...
Daniel Lopez over 1 year ago in Edge Data Store / Egress 0 No status

Use EDS to download OCS and PI data for use as a local data cache for Data Science in tools like R-Studio and Jupyter Notebook

As a data scientist, I would like to set up types, streams, and query data from OCS to use locally on my desktop in data science languages (e.g. R, Python) and tools I use (R-Studio, Jupyter Notebook) so that I can rapidly try different numerical ...
Guest over 3 years ago in Edge Data Store / Analytics & Calculations 1 Tell us more

EDS: security/authentication mechanism

Customer wants to deploy EDS at machine level to collect data from PLCs which are directly connected to the machine which would imply a proper security / authentication mechanism for EDS
Guest over 3 years ago in Edge Data Store / General 1 Tell us more

Add Analysis Categories to PI Builder

When using Pi Builder to retrieve and edit analysis parameters, analysis categories would be a nice inclusion, the only way to edit now is with PSE
Guest 10 months ago in AVEVA™ PI DataLink™ / Settings 0 No status

Data Retention configuration for EDS SDS

We have no information regarding data retention. This could be clarified. Data retention should be better configurable as of now, only the stream size can be configured just by estimation. Provide a sizing and calculation tool for Edge Data Store ...
Hans-Otto Weinhold almost 2 years ago in Edge Data Store / Historian 0 No status

Have the possibility to disable OIDC authentication in PI DataLink

Add an option to disable OIDC authentication in PI DataLink.
Eduardo Mirra Galante Miller almost 2 years ago in AVEVA™ PI DataLink™ / Settings 0 No status

Documentation of EDS Modbus TCP Adapter needs to be updated on removed 32-bit register support for Modbus TCP Adapter

Challenge: The current version of PI Adapter for Modbus TCP does not any longer support 32-bit Holding/Input registers as this is outside of the Modbus specifications. However, in some cases, 32-bit register values have to be read from 16-bit regi...
Hans-Otto Weinhold about 2 years ago in Edge Data Store / Ingress 0 Planned

EDS: Modbus Serial Connector

Ability for Modbus Serial connector to write data to Edge Data Store.
Guest over 3 years ago in Edge Data Store / Ingress 1 Declined

Provide an Setting to Switch Between Absolute and Relative Cell Reference

Create an absolute or relative cell reference user configurable setting. Note: This was previously Enhancement 19354OSI8.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Settings 1 Declined