To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 28 of 5194

Built-in SQL database backup job

As a PI Administrator, it would be useful for the PI Vision SQL database installation to also create a PI Vision SQL database backup job like the AF SQL Scripts already have. That way I do not have to configure the PI Vision SQL backup job manuall...
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 0 Declined

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Implement PI Vision SQL Database Schema Version Checks

Because PI Vision upgrades exist in two parts (application, database), the database portion may be omitted accidentally on occasion. In these situations, it would be useful to implement application pool checks to ensure the database schema version...
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

PI Vision upgrade script should have a success message

PI Vision upgrade script (go.bat) should be able to identify the database version before verifying if legacy table exists. And there should be a success message.
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 0 No status

Coresight SQL database collation handling

Coresight SQL database explicitly specifies SQL_Latin1_General_CP1_CI_AS collation for some of the string columns. The system collation should be used instead.
Guest over 3 years ago in AVEVA™ PI Vision™ / Installation & Upgrading 1 No status

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status