To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 21 of 5194

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Add 'Time Zone = Server' to PI OLEDB Enterprise

'Time Zone = Server' is available in PI OLEDB Provider, but has not been added to 'PI OLEDB Enterprise'. We have PI Data Archives in multiple time zones and require the ability to select the data in the server time zone.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 2 Declined

Log device information when the Connector receives errors from a device

Currently the Connector logs when it receives errors, but does not print information that can be used to determine which device is reporting the errors. We currently need to perform a wireshark trace to look at the individual packets to determine...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Distribute-Broadcast-To-Network broadcast for Discovery Tool and Connector

When running the discovery tool from a subnet with no BBMD to query BACnet devices on a separate subnet, it seems like the auto discovery tool is seen as a ‘foreign device’, so the devices do not respond correctly. When analyzing a Wireshark trac...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Provide the option to install the PI OLEDB Enterprise Server Agent without installing PI RTQP Engine

Currently if you are using the PI SQL Data Access Server (RTQP Engine) 2023 SP1 install kit to install the PI OLEDB Enterprise Server Agent, you must also install the RTQP Engine as well. As a PI System Admin, I would like the option to only insta...
Bethany Jewett 9 months ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 No status

Add in the Element Hierarchy table information to determine the primary reference of a copied reference element

When an element is copied as reference (parent-child) elsewhere in the tree it then has multiple parents. One of it is the primary parent. This information needs to be added to the hierarchy tables.
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 1 Declined

Allow the BACnet Connector to handle responses with an LVT that does not match the request

Currently the BACnet Connector expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Connector cannot parse the data in the response. For example: Request from Connector, LVT=1 Re...
Nico Cha almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Allow PI OLEDB Enterprise client to specify which member of a PI Data Archive Collective to connect to.

Enable functionality for PI OLEDB Enterprise that will allow the client to specify which member of a PI Data Archive collective they wish to connect to. This functionality has already been enabled for PSE and would like something similar for PI OL...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 0 Declined

Increase the maximum timeout for the BACnet Discovery Utility with the PI Connector for BACnet

If a user has many BACnet devices/objects discoveries can take some time. Since the BACnet Discovery Utility has a maximum timeout of 240 seconds, this utility can cannot be used in these scenarios and manual creation of the csv is required which ...
Nico C almost 2 years ago in PI Connectors / PI Connector for BACnet 0 No status

Automatically update Transpose Function in SQL Commander when referenced Element Template name is updated

In PI SQL Commander, users can create Transpose Functions that are linked to Element Templates in AF. When the referenced Element Template is renamed in PI System Explorer, the Transpose Function in PI SQL Commander is no longer able to find the E...