To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 134 of 5194

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Drag and drop display(s) into folders

Ability to directly on PI Vision drag displays into folders to move them. Furthermore, select multiple displays and drag & drop them into a folder.
Carlo Villarreal Escudero about 3 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Self-Heal PI Vision post-SQL outage

When the SQL Server (or listener / AG) are unavailable and restored, PI Vision does not recognize that the database is available / connectable again. This requires restarting PI Vision after a SQL outage to ensure the application is usable again. ...
Tyler Engelhardt almost 2 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Set the order of the root import folders when more than one root folder is defined

Customer Issue: Import folders are listed in the order they are added which makes it difficult to sort them if more folders need to be included later. Enhancement Request: Allow administrators to set the import folder order. Workaround: If pos...
Guest over 3 years ago in AVEVA™ PI Vision™ / Administration 0 Declined

Detailed Display Status Report

When building displays with a large number of attributes being used it is very easy to make mistakes. Applying the wrong tag, or duplicating tags, is very easy to do but hard to troubleshoot. ProcessBook had a display status report. It is similar ...
Brian Bolton almost 3 years ago in AVEVA™ PI Vision™ / Administration 1 No status

Support container deployment for PI Vision

As a PI System administrator, I am looking for the flexibility to quickly provide new PI Vision deployments to scale up overall visualization capacity and allow for easy separation between user communities. It would be ideal if it were possible to...
Clint Ostby about 2 years ago in AVEVA™ PI Vision™ / Administration 0 No status

Add Time Offset Option to OPC UA Connector

Please add a time offset option to the OPC UA Connector, similar to the old OPC DA interface (see attached screenshot). In come cases the OPC UA server may not actually be sending timestamps that are in UTC (ex. in local time) so an offset is nee...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status

An import-export feature for PI Connector for OPC UA similar to the one used to configure OPC DA points

Having to select the OPC UA server points to import from a list with thousands of points where a naming rule is not followed is a never-ending task using the OPC UA Connector web interface. My suggestion is to create an interface similar to the on...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 1 No status