To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 111 of 5194

Add Digital Set in OPC UA

Possibility to specify the digital set of a digital tag (CLOSE/OPEN)
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Make the PI Connector for OPC UA support the use of the "Reverse Connect Client Facet"

In the reverse connect methodology - The server opens the socket and calls the client with a Reverse "Hello" message. After that, the client will use the already open channel (which initially fails with establishing the handshake) and call the nor...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 3 No status

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo over 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable setting tag attributes in the PI Connector for OPC UA (gen1 and gen2)

The PI Connector for OPC UA (gen1 and gen2) should have ways to set tag attributes. There should be way to automatically set the PI point attributes like point and data security.
Paul Kim about 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Auditviewer separation of roles

I want to separate the security roles between 1) the ability to run an Auditviewer report and (potentially) associate a change control record to a configuration change and 2) the PI Admin Role in order to minimize security risk.
Guest over 3 years ago in AVEVA™ PI Server / Security 1 No status

Be able to configure PI AF security in a single PI System Explorer window

Currently, there are 2 windows to configure PI AF security, and it is a pain to switch between them: File → Database → Edit Security, which is used to assign permissions to identities File → Server Properties → Identities tab and Mappings tab, whi...
Kenneth Barber over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Have an option in AF Security to not pass down database security to newly created objects

Use case: We want to give a user read access to a single element. All future elements created inherit the Database level Security, meaning the user will also have read access to all future created elements.
Guest over 3 years ago in AVEVA™ PI Server / Security 0 Declined

Hide Certain PI Point Attributes from Users

Implement a way to hide the contents of a PI point attribute, specifically the Instrumenttag attribute. With many PI interfaces, the InstrumentTag attribute will store the IP address of the source, and we (as well as many other utilities) have a r...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 Declined

User rights for viewing analytics

In many cases analytics should not be visible to everyone having right to view an AF-Database. Should be possible to direct whom should have view access to analytics. This is an extension to the obivious right to change analytics :)