To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 405 of 5219

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Set name of Event Frame on close (or by the value of an EF output attribute)

It would be useful if Analysis Service would set the name of the Event Frame on close rather than open. The use case is customer wants to dynamically set the name by a value of an EF attribute (possibly an EF output attribute) - for example, if a...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

multiple instances of analysis service

As a PI administrator I would like to be able to create multiple instances of "PI Analysis Service" windows service for these reasons: - avoid new potentially problematic analysis from affecting the ones that are operational and working correctly ...
Phillip Riesinger over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 6 No status

Add a PI Analysis Service performance counter to track stopped analyses

The PI Analysis Service has performance counters to track the number of running analyses and the number of suspended analyses, but there is not one that tracks the number of stopped analyses. Currently, the only way to monitor how many AF analyses...
Bethany Jewett 9 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Enable tracing for one individual Analysis

On a highly loaded system with thousands of analysis i have one analysis that is misbehaving, missing executions but no skipped count, etc. Currently tracing enables tracing for ALL analysis creating an ocean of logging to plough through for that ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Scheduled backfilling for a specific time frame on analyses

Add the capability to perform scheduled backfills for a specific time frame, for analyses created on PI System Explorer.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 9 No status