To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connector for OPC UA

Showing 65 of 4768

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 1 No Status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Description

The OPC UA connector automatically creates tag descriptions when new tags are loaded (tag only mode). This behaviour may not always be desired . In our example we want to change the descriptions to something more meaningful. It would be useful ...
tdeibe01 over 1 year ago in PI Connectors / PI Connector for OPC UA 1 Evaluating

Implement similar functionality as the /ta flag from the OPC DA interface

Using the OPC UA connector there is no equivalent to the /ta flag in the OPC DA interface, which ensures when a value significantly changes in a short time period that it does not interpolate. The current work around of setting the Step attribute ...
caffreys_col 3 months ago in PI Connectors / PI Connector for OPC UA 0 No Status

When a 'Bad' value is written to PI, store the actual Opc.Ua.StatusCode that is returned by the server in the logs

Since the actual Opc.Ua.StatusCode cannot be stored directly in the PI Point (can only use SYSTEM digital states), when a 'Bad' status code is received by the connector, the actual StatusCode should be stored in the logs (verbose or information) w...
Gabriel Verreault over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Add Digital Set in OPC UA

Possibility to specify the digital set of a digital tag (CLOSE/OPEN)
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Import function for data selection in PI Data Data Collection Manager

During setup of a new data source we always face a long list of several thousand tags where we only need a couple of hundred. We have also a list with tagnames available as .xlsx or similar. The idea is to have an import function for that list to ...
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 2 No Status

X509 User Token Policy

Allow future releases of the OPC UA Connector to support user authentication via certificate or IssuedToken instead of only through user/password or anonymous connection.
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 2 No Status

Access to "HE" identifier-type historical data in OPCUA servers

Being able to retrieve "HE" identifier-type historical data from OPC UA server s if they are indeed presenter there/. This type of data is important as it provides historical alarms and events which were captured on the source OPC UA server
Guest over 1 year ago in PI Connectors / PI Connector for OPC UA 0 No Status

Create a utility to reprocess corrupted buffer files

It would be very useful to have a utility same as there is for PI buffer Subsystem files for connector buffered files It is common to get corrupted buffer files and we depend exclusively on tech suppport to get that data availabe
asanzacedo 11 months ago in PI Connectors / PI Connector for OPC UA 0 No Status