Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 173 of 5258

Add support for the Kongsberg WITSML server to the PI Connector for WITSML

No description provided
Guest over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

IEC 60870-5-104: Interrogation Type

Currently, the Interrogation Type selection options are: - General interrogation - General and groups interrogation - General, groups and counters interrogation There should be an option for General and counters interrogation
Gabriel Verreault over 3 years ago in PI Connectors / Other specific PI Connector 0 No status

Allow filtering of source points

In the HabConnect Connector the only filtering of source composite ID's for inclusion into PI is through use of wildcards. As a user I want to filter not at the query level to sampler, rather filter out tags in the result set (preferably using reg...
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

If data contains asset information, this data shall be written to asset related streams

Challenge: We have (CSV) data files which come from Laboratory or other measuring equipment where the data lines contain information on which asset the measurement was taken from. In our particular use case, we read sample data from lab analyzer w...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Adapter for Structured Files - User friendly interface

Make the configuration experience more user friendly. Add a user interface for adapter configuration and management.Today, this adapter is too configuration intensive
Guest over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 0 No status

PI Connector for IEC 61850 is unable to retrieve more than 100 top-level objects in the hierarchy

Currently, PI Connector for IEC 61850 will only retrieve the first 100 top-level ("vmdSpecific") items in the source object hierarchy during its initial request. If any reports exist in items beyond the first 100 top-level objects, then the Connec...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status