To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 173 of 5192

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

PI adapter for PI-to-PI

We need a new robust product to support data transfer between PI servers in separate domains (operational network --> business network). This product would need to support the following: Highly available remote management/deployment multiple in...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 3 No status

PI Adapter High Availability Resilience

Problem Summary: The client failover service for PI adapter is not highly available. If the client failover service node is unavailable, then the PI adapter instances that it manages will lose failover functionality. This is further exacerbated if...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / General 1 No status

Detect and monitor which OPC UA server the PI Adapter is connected to

When configuring a PI Adapter to leverage server-level redundancy, it is not currently possible to monitor which server instance the PI Adapter is connected to. Surfacing this information would allow server administrators to better monitor the hea...
Giulio Cattarin over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Enhance the Timestamp data type to support all the formats allowed on .NET

Use case: ISO 8601 timestamps (2019-07-08T18:48:02+00:00), would be much easier to parse with full .NET datatime format support. It would also allow the connector to be consistent with the dynamic timestamp formatting that follows https://docs.mi...
Gabriel Verreault over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Add another Archive Mode option for the PI Interface for UFL

There should be a way to configure the PI UFL interface to both discard duplicate events (same value at the same timestamp) and record multiple unique values for the same timestamp when these events come from multiple data files. For example, if...
Guest over 3 years ago in AVEVA™ Adapters / General 0 Tell us more

Add the ability to write to a point using an attribute other than tag name

Provide the capabilities of mapping a UFL data point to a PI tag using a PI Point attribute other than the tag name.  For example, we’ll have a data file from another database that uses a different ID than our PI point name. Could we write to...
Guest over 3 years ago in PI Connectors / PI Connector for UFL 2 No status

Add ‘No Replace’ mode to UFL Connector

Currently the only PI Data Archive ‘Store Mode’ options are ‘Insert’ and ‘Update’. I’m currently working on a project where a large quantity of data needs to be downloaded daily from the internet using the REST client node. To reduce chances of da...
Mic Paluszak over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Configure target PI/AF/DB at datasource level

Actually the UFL Connector sends data to all of the listed PI Data Archives and AF Servers in the server list configured in administration page, so it's not possible to send different data to different PI DA or AF databases with a single UFL Conne...
Carlo Pedroli over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Try catch management

Actually, if an error occurs during data processing, datasource stops immediately execution and skips the remaining rows. Try catch or similar could increase stability of data acquisition.
Carlo Pedroli over 3 years ago in PI Connectors / PI Connector for UFL 1 No status