To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 54 of 5194

Interpolate Step=On Tags

There are tags that should be kept as Step=On but there is certain cases in which someone should be able to easily bypass the typical interpolating rules (interpolation that follows the step parameter) and allow for a true interpolation between va...
Matt Voll over 3 years ago in AVEVA™ PI DataLink™ / Functions 4 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Wonderware Historian Connector - Allow Custom Tag Naming

The Wonderware/AVEVA Historian has some different illegal characters than PI tags and there are also cases where a single tag prefix isn't sufficient (e.g. when storing data from multiple buildings in the WW Historian). The Connector should have t...
Sublette-Sanofi over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Add support for all the AFData methods as well as the generic getvalues method

Please add total support of using DataLink to pull data with all the methods available to AFData.  In my commercial organization we release software to aid our customers in retrieval of PI data.  We can't release software in which the AF...
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined

Being able to Copy / Paste or "Copy Drag" calculated data strings

Be able to drag a cell's calculated data formula with using cell references should speed up report creation. Currently, have to create new calculated data each time, fill each cell requirement instead of copying down.
Lucas Renz over 2 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Fetch previous change of value (and its timestamp) from compressed data

It is valuable to extract the previous change of value and its timestamp without full dump of compress data. If that value could be specified, the feature is even more usefull. Example: a time series has the state of an alarm and the current value...
Guest over 2 years ago in AVEVA™ PI DataLink™ / Functions 0 No status

Disable Meta data collection for the PI Connector for Wonderware Historian

We would like to have a way to disable the PI Connector for Wonderware Historian's ability to  collect descriptions and engineering units in the historian.  These can be incorrect at times in the Wonderware Historian.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 1 No status

PI Connector for Cygnet - Historical Data Recovery

The PI Connector for Cygnet is normally used for real-time data acquisition. But, some times it becomes necessary to migrate large volumes of historical data between Cygnet and PI. There is a back filling application that can be used to do this, ...
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

"Show value attributes" option for Current Value and Archive Value functions

Include a "Show value attributes" option on the Current Value and Archive Value functions.
Guest over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined

Display a parameter tooltip (IntelliSense) when typing functions manually

Please add a tooltip or equivalent to show the arguments of the PI DataLink functions when you are entering the functions manually, similar to the tooltips that appear when you use native Excel functions.
Kenneth Barber over 3 years ago in AVEVA™ PI DataLink™ / Functions 0 Declined