Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1362 of 5194

Update 'Modified date' of an event frame when an attribute is filled in manually (for example with reason code)

At this point, only the modified date of an event frame is updated when the event frame is created or when a backfill or recapture is performed. For transferring data to a data lake or warehouse, it would be very useful to see which event frames c...
Bart Van De Gehuchte about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Utilisting exisiting PI Datalink functions within Asset Framework for attributes

PI AF attributes (used for analyses) lacks the ability to filter for conditional values. (e.g. the function PIAdvCalcFilVal). Often data can be represented poorly for calculations and there isnt an easy way to filter the outliers and use that valu...
Mitchell Davidson about 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Ability to find the EFGEN configuration server name and interface ID for Event frames

It would be great if we can know from which machine EFGEN interface are configured and the corresponding EFGEN interface Id for a particular event, so it will be easy to troubleshoot the issues occurring in event frame generation.
PradeepKumar Logandurai about 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Installer screen should read 'PI Data Archive Install Directory' instead of 'PI Data Archive Directory'

For an upgrade - misleading - could be interpreted as the folder where PI archives currently reside.
BruceMcCamant about 3 years ago in AVEVA™ PI Server / Installation 0 No status

Provide a tool (in PSE?) to assist management of analytics scheduling offsets

We recommend customers use offsets to distribute scheduled calculations across time but there is not a good way manage this.Propose some utility to list a group of all scheduled analyses by same period, users supply X number of offsets and then th...
Brian Deslatte about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Provide visual indication of attributes that are used as calculation inputs or outputs

it would be useful if there were a way to easily identify which attributes represent inputs to an analytic versus those which represent outputs.
Laurie Dieffenbach about 1 year ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Add Archive Statistics to AFSDK

I would like to be able to request current Event Queue, Primary Event Queue, and Archive Events counters programmatically in order to perform my own throttling when backfilling from external systems. This becomes especially important if you also h...
Le vi over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

PI Notification Send PI Vision HTML display not a screen shot

We have several reports that take advantage of collections in PI Vision. Collections let you view data across multiple assets sharing a template. Within a collection, we have several trends, which require you to scroll down. We need to send these ...
MattBa over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

PI Connector for Wonderware to be able to detect dll files in other drives other than C drive

Had a customer that just installed PI Connector for wonderware of current version (v1.6.9.14) and his connector is unable to start. Upon discussion after troubleshooting, it was noted that the directory where dll files can be located on customer's...
Chaur Ann Poh about 2 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Document and have a dialouge that informs the user that Analysis backfilling does not observe compression settings.

Currently when backfilling an analysis with the PI Buffer Subsystem turned on, all values are sent to the PI Data Archive uncompressed. This is because values are perceived as out of order and these settings are not observed. This should be mentio...
Guest over 3 years ago in AVEVA™ PI Server / Help / Documentation / Videos 0 Declined