We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 147 of 5194

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Wrap Text In Trend Legend

The ability to wrap text in a trend legend would be beneficial aesthetically when including long labels for trend objects.
Guest over 1 year ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Allow option to set screen size

We're recreating DCS screens that have a specific size (11x17 when printed) but there's no way to match this in Vision (especially since we can't set a specific symbol size, such as with a scale of 1-40). It'd be great if there was a way to set th...
Kelsey Bobeck over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 Declined

Support URN in addition for URI for OPC UA Server redundancy

As stated in the documentation "Some OPC UA servers use URNs instead of URLs, which is not currently supported by this adapter.", adding support for URNs would increase the servers the adapter is compatible with.
Mike Horrocks 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Hide trend scale range

For digital tags or Enumeration AF attribute, do not want to see the scale or scale range, because these values is not relevant to my values.
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 0 No status

Allow custom menu/navigation bars

All the Pi Vision screens I have seen seem to include a custom menu bar that the user creates for internal navigation that is manually copied and pasted to each screen every time there are updates to the structure. Instead, there should be the abi...
RyanCarpenterAd over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 1 No status

More control over pop up and ad hoc background color

Currently the background for ad hoc and pop up trends is controlled by the background color of the display and the background color of trends on the display. It would be nice to have more control over this setting. For this particular use case, ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 5 No status

Ua Server force failover / improve failover logic

Let me preface this by saying that I know it is a workaround for a non-compliance with the OPC UA specifications. The point is that the situation described below is unfortunately all too common and the workaround is needed. It often happens that t...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status