Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1616 of 5259

OPC UA Adapter: support Namespace index change after OPC UA Server restart

AVEVA adapter for OPC UA should support changes in the Namespace index that can happen after an OPC UA Server service restart. Currently, if the Namespace index of the source signals change, the adapter stops receiving data for every point in that...
Alvaro Bilbao 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

add interface node information in audit trail record

the audit record information only have the instance information, not have the interface node information. If the instance service id is the same, the audit information can't tell which interface node it is. The audit trail record should contain th...
Emily Ni 5 months ago in AVEVA™ PI Server / Data Archive 0 No status

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Move Auditviewer function away from local PI System access

I want to run the Auditviewer function as a unprivileged remote user, moving away from the current requirement to run as a local user on the PI Data Archive Server.  This is so I can minimize security risk associated with local user access on...
Guest over 3 years ago in AVEVA™ PI Server / Security 1 Declined

Provide a central point to manage the security for the whole PI System

Instead of having several admlin tools to manage the security for data archive, AF, PI Vision, PI Integrators Could you provide a centralized security management interface which could manage all the existing and upcoming OSIsoft tools
jerome.boudon over 3 years ago in AVEVA™ PI Server / Security 1 No status

Incremental backups are not possible because of frequent backfilling

Occasional back filling of data would cause 5 TB of archives to be backed up with incremental backups. This is frustrating because only a few KB of data is changed in each archive. Can OSIsoft provide a way to backup only the data that has changed...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Allow users to specify time zone per input

As an analysis user in a multi-national corporation with data from different time zones, I want to be able to designate a time zone per input when configuring analyses so that any relative time used in the analysis refers to the correct data.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 Declined

Allow Rollup analysis to output to to an Analysis Data Reference

I would like there to be a way to output the results of a rollup analysis to an Analysis Data Reference, so that I can view a trend without having to write to a PI point. Currently, there is no option to have a rollup analysis that does not write ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 7 Declined

Provide a way to backfill/recalculate analyses from Analysis Template tab in PSE

It is difficult to find all the analyses from template to backfill/recalculate after making changes in Analysis Template.  Currently one has to navigate to the Management plug-in, do some sort of search/filter, then queue the analyses.  ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Analysis - Remove backfilling

When a failover occur or at service startup, ALL analysis configured for backfilling executes based on the last configured backfill/recalculate timerange. There is actually no feature to manually remove a configured backfill on a specific analysis.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 3 No status