Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 101 of 5197

PI Adapter for OPC UA should preiodically retry to subscribe to each node for which subscription failed at startup

Currently the PI Adapter for OPC UA tries to subscribe to all the OPC UA nodes configured in the Data Selection configuration at startup. However, when as issue occurs during the subscription to an OPC UA node, that node will not be included in da...
Bernard Lafrance almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

PI Adapter for OPC UA data conversion

As a PI System Administrator, I would like to be able to apply conversion factors to the data that is being gathered from our OPC UA server. This would allow us to get data in the format/units we'd like, without requiring extra tags and/or calcula...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

PI Connectors buffering (Tau) - provide configuration options

As a PI Administrator, I would like to be able to DISABLE or configure Tau buffering SO THAT after a network outage the flood of data doesnt overload my network switch and PI DA. My current use case doesn't require the data that may be lost during...
Guest over 3 years ago in PI Connectors / General 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee 6 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

Prevent PI Adapter for OPC UA from modifying/override stream overrides and metadata upon restart

Problem: I have configured PI Adapter for OPC UA to collect data from an OPC UA Server. Since UoMs are not assigned properly, I created stream overrides in AVEVA Data Hub to assign the proper UoM to the particular stream. I also associated stream ...
Hans-Otto Weinhold over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 4 In development

Allow the AF root element name to be configurable

The root element in AF is determined by the Connector code.  Allow the name of the root element to be specified by the user.
Clint Ramsey over 3 years ago in PI Connectors / General 4 No status

Increase the default log size

The current default log size in the event viewer is 1MB. Although it can easily be increased, a larger default (100MB+) would allow to catch errors the first time they occur and allow for further troubleshooting then having to change it and have t...
Gabriel Verreault over 3 years ago in PI Connectors / General 0 No status

PI Connector for MQTT - support more generic JSON formats

While the existing support for Sparkplug MQTT format is helpful, this connector would be more useful if it also supported a more generic JSON format.
Guest over 3 years ago in PI Connectors / General 3 Declined

option to not collect quality

Quality is not supported by the OPC UA Server/always zero.
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Tell us more

Put a REST endpoint on all connectors

It would be very useful to see the data flowing through a connector at the edge, or even the data buffered in a connector. Every connector could have a rest endpoint with the same methods as PI Web API. Possible uses: -Diagnose connection/configu...
Guest over 3 years ago in PI Connectors / General 1 No status