To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1406 of 5286

Order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer

I would like to be able to order by name (alphanumerically) the Analysis in the Management tab in PI System Explorer after retrieving a list of analyses through a search/filtering. This could be done by clicking on the Name column.
Jose Sanchez Colunga over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Error handling for OPC UA Server nodes with "Null" data type

Using a combination of Honeywell Experion OPC UA and the Aveva OPC UA Adapter, we have observed that when an instrument physically fails in the field or goes offline / stops sending communication to the Experion server, it may appear in the Honeyw...
ChrisMcKee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Trigger automatic recalculation for snapshot changed values

As for now, automatic recalculation is not triggered by changes on snapshot (KB01790), which means auto-recalculation does not work with snapshots values. The idea of it doing otherwise is to help users that mistakenly added a wrong new event to ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 9 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Allow selection of output timestamp for values written by the outputs at close feature in Event Frames

It would be nice to have the option to select either starttime or endtime of the eventframe as the timestamp for the value that will be written a PI tag using the Outputs at close feature in Event Frames. Currently, it will only write the value wi...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 5 No status

Editing analysis templates should not clear notification trigger conditions.

Currently, if you have notification rules that are triggered by an event frame analysis template with additional attribute-based trigger rules, those additional attribute-based trigger rules get cleared any time you update the analysis template. T...
Kevin Wood about 1 month ago in AVEVA™ PI Server / Notifications 0 No status

Allow REST config tool to generate json text for the user

In addition to the "test send" button, the JSON generation tool should have a "view JSON" button that generates the actual JSON body that PI will send. This will make troubleshooting much easier, and give users better understanding of things like ...
Kevin Wood about 1 month ago in AVEVA™ PI Server / Notifications 0 No status

View in SMT which connections are OIDC in Network Manager Statistics

Possibility to identify in SMT which connections are OIDC, besides the "Is TLS" in Network Manager Statistics.
Eduardo Miller about 1 year ago in AVEVA™ PI Server / Security 0 No status

Increase the allowed password length for AF Linked Table "Supply Password" connections

Currently the maximum password length for AF Linked Table connections using the "Supply Password" option is 15 characters. This length limitation should be increased to at least 25 characters.
Guest over 3 years ago in AVEVA™ PI Server / Security 2 No status