Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 547 of 5273

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Allow NaN value or NULL

Currently, when sending PI data to CONNECT data services, if an atribute has NaN as value, the whole asset is removed from the transfer. Would like to support NaN or have NULL values in CONNEC
Max McKay over 1 year ago in PI to CONNECT / General 0 Tell us more

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Provide additional features to support debugging

When first setting up the agent, there can be scenarios where there a number of errors to work through - for example tag not found. Summarization of errors and an alternative to event viewer would aid debugging.
Guest about 2 years ago in PI to CONNECT / General 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

Support VHS point History recovery for PI Connector for Cygnet

VHS points in Cygnet contain historical data. On startup, disconnection and at will, the connector should should attempt to recover history.
Guest over 3 years ago in PI Connectors / PI Connector for CygNet 0 No status

Program objects (BACnet object type 16) also bought through by the connector

The program object description is often very useful to understand what the various object instances relate to. At our site the description holds the Asset designation and that would allow correct assignment of the analogue and binary object instan...
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Wonderware Connector - History Recovery

Wonderware Connector has limited historical data recovery capabilities. It can cover a few days back in time but has not been designed to perform both realtime values and configurable history recovery period as both processes are synchronous. An o...
David_CHATEL over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 Declined