To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 156 of 5194

Subscription Templates

I'm currently working on a project to push notifications immediately to a database, via REST delivery endpoint. However, each delivery endpoint needs to be subscribed per notification rule, AND also configured. Configuration can take awhile to do,...
Milin Roshan over 2 years ago in AVEVA™ PI Server / Notifications 0 No status

Table-Valued Function

Currently it is not possible to define filter definitions for Table-Value functions.With DataLink I'm able to define to build an average for a process value by using a defined filter method. e.g. calculating an average current of an engine while t...
Christian Benitz about 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add support for unit conversion

Please add a "Canonical UOM Per UOM" or "UOM Per Canonical UOM" column (not necessarily with those exact names) to the UnitOfMeasure table. This column would contain the conversion factor needed to convert between the UOM and the canonical UOM, si...
Kenneth Barber over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add RTQP PI SQL support for parameter type cast

PI DAS (RTQP Engine) 2018 SP3 Patch 1 lacks support for type casting input parameters of a table valued function. For example. this simple example fails to create a table valued function: CREATE FUNCTION [MOMS].[fact].[getInstrumentOperationalDat...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Add RTQP PI SQL support for default value of function parameter

The current version of PI DAS (RTQP Engine) does not support the definition of default values for table-valued function parameters. This is a rather bleak omission, in my view. For example, the following will fail to create the table-valued functi...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI SQL Client 0 No status

Create Analysis and Notifications when limits are set on attributes

As a Notification user I would like a one-click way of configuring a notification on the limits I have set on the attribute so that I spend less time configuring a simple notification such as this.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

Show different status icon for Notification when it's Event Frame is not Running

For notifications triggered off of an event frame analysis, it is possible for the event frame analysis to be turned “off” (not showing green checkmark) while the corresponding notification still shows a green checkmark. This seems slightly mislea...
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 Declined

Specific Number of Required Acknowledgements for an Escalation Team

A way to require a certain number of acknowledgments for an escalation team? (ie: Only stop notifying if 3 or more people of my 5 person escalation have acknowledged the notification)
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 Declined

Dialog for configuring notifications

I would be good to have a dialog for configuring notifications setting as it was available in the old notifications version. It seems strange to me to change values in the configuration database.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 0 No status

Option to change (or extend) mail format on element level

For some elements, i would like to add some extra agreement specific text to the notification mail. There is currently no good method for doing this, since this is locked to the template. I suggest that which mail goes out to each subscriber cou...
Haavard over 3 years ago in AVEVA™ PI Server / Notifications 0 No status