To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Option to not capture value for event frames generation

As an engineer I need the option to not capture values for event frames generation so that if I have out-of-order events, I don't have to recapture the values. Note: This was previously Enhancement 114349.
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

Add a function to calculate the week number of the year

In order to calculate the current shift operating at a plant, I need to calculate where in the 28-day cycle the current week is. Knowing which week of the year it is allows me to do that. Note that current PI weekday functions always count Sunday ...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 Declined

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 11 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration

Adapter to failover when there is egress issue

When connection to the datasource are all good for all the adapter failover members, but the primary adapter having issue connecting to the PI web API (egress) for example, adapter does not failover. Unlike PI Interface UNIINT failover, when there...
Ee Sheing Lee almost 3 years ago in AVEVA™ Adapters / General 2 No status

Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
taterhead247 almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Classic Mode for Adapters

One of the big issues we have with adapters (outside of the lack of write capability) is not having the same control over creating and editing tags that we have with PI interfaces. As we talked about the adapter automatically creates PI tags or us...
Brian Rock over 3 years ago in AVEVA™ Adapters / General 5 Future consideration

Configuration reconnection (retry) time on the adapter

OPC UA adapter takes 5min by default to reconnect to a load balanced PI Web API pair which failed over.
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Multiple PI to CONNECT agents for one PI Data Archive

Aside from our main AF Server setup used for numerous use cases like energy, OEE, etc, we have created a second environment of AF Server / AF Analysis / SQL Server to isolate the monitoring of a critical process. We are still making use of a singl...
Christian Leroux about 3 years ago in PI to CONNECT / General 0 No status

processor rate(s) for Processor properties of Modbus Adapter Service Health

Visualize and understand usage when trended with other diagnostic properties.
Guest 2 months ago in AVEVA™ Adapters / General 1 No status

OMF Egress health to include stream count

Validate stream count for scenarios where there are multiple Components
Guest 2 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status