Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 730 of 5194

PI Analysis Performance Checker

Currently PI Analysis Service has a built-in Statistics tool in PI System Explorer. It is able to show statistics regarding Evaluation and Calculation Lag as well as Skipped Evaluations and some other important information. PI System Explorer ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 1 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest over 3 years ago in PI Connectors / General 0 No status

Configurable input REST data queue file size for PI Connector for UFL

We're working with a large AMI customer, using the PI Connector for UFL as a REST server endpoint to receive meter data. However, during large interrogations, the amount of messages received can be faster than UFL can process, leading to overflowi...
Kendell Jillson about 2 months ago in PI Connectors / PI Connector for UFL 0 No status

Allow writing arrays as a time series to an output

I would like to be able to configure outputs in an analysis to write at multiple time points (which are defined by the result of an array function). My use case is to: 1. Configure an attribute as a Time Series Table Lookup 2. Create an analysi...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Tell us more

Enlarge area for editing analysis expressions

When editing an Analysis Expression, only 4.5 lines appear. It would helpful if more lines appeared (greater than 20 lines).
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status

Selectable Write Mode for Analyses

As an analysis user I would like to define what should happen if multiple triggers occur with the same timestamp. Currently AF analysis are using "Replace" mode when writing to the archive (meaning if multiple triggers have the same timestamp, the...
phsutter over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 7 No status

Which tags are being used by a PI Analysis

As a PI Administrator, I want to know which tags are being used at which PI Analysis so I can know exactly if there is already another Analysis writing to a tag and avoid duplicated or wrong data.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 11 No status

PI AF - Child Event Frames using different template to parent

We currently have Event Frames generating for machine faults, with child event frames then tracking things such as maintenance team response time etc. Leveraging this data in excel reports is proving difficult however due to the Child Event Frame...
alan.mccarthy over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 3 Declined

Output tags on connectors

Sometimes we need to send data back to our sources. Connectors should support output tags
Alan Izar over 3 years ago in PI Connectors / General 8 Declined