To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 456 of 5259

Improve usability of TagNum function

The TagNum function seems to be the only function that requires a double quote as opposed to single quotes. Many other TagXXX functions call for single quotes for its attribute or PI Point arguments.
Jinmo Yi over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Thorough Analysis service message logs

Having more thorough and detailed messages for the Analysis service in the event logs, especially upon startup. Environment details + Language settings that the Analysis service is using should be mentioned in the startup logs in order to better ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow Analysis timestamp override feature to output milliseconds

When using an analysis variable as the output timestamp, it appears that the actual output timestamp is floored to the nearest second, shaving off any millisecond count. This is not a huge priority on our end, but I wanted to ask in case it was a ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Remove tag need for Exit() and NoOutput() in analysis

Allow analysis outputting to Analysis Data Reference attributes to make use of the functions Exit() and NoOutput(), instead of requiring only PI Point Data Reference attributes.
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

CONNECT Agent for AVEVA Plant SCADA (Citect)

AVEVA Plant SCADA 2020r2 and newer, has an OPC UA Server, so the AVEVA Adaptor for OPC UA can be used to send data to CONNECT data services (AVEVA Data Hub). However native connectivity like the PI-to-CONNECT Agent or the System Platform Connector...
Guest almost 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Make "In" operator compatible with arrays within AF Analysis

We have many calculations following this basic pattern - take recorded values of one attribute, apply a filter (using FilterData), then retrieve values of a second attribute at the filtered timestamps of the first attribute. Currently, we cannot r...
Gregory Malek almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Overload the Convert function to allow a input UoM and output UoM for unitless values

For unitless values you can assign a unit of measure by using the Convert() function. To further convert this to another UoM in the same class you need to nest another Convert() function. For example, Convert(Convert(3600, "s"), "h")) It would sim...
Mike Horrocks almost 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status