To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Periodic trigger monthly and yearly

I would like to have monthly and yearly periodic trigger for Analysis-Expression and Event Frame Generation. Currently I have to use the daily trigger and check in the analysis if the month or the year changed. In case of “false” there is no outpu...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status

PI Adapters should handle good NULL Values like PI Connectors and submit to the archive

A PI Connector reading a Null value in good quality send it to the Archive A PI Adapter skip the value, this gives in the archive a wrong picture. please enable the PI Adapter to submit also Null values with good quality to the archive like PI Con...
Markus Rombach 5 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 No status

Support for additional Complex Data Types for all Adapters

Request to enhance the Adapters to support more complex data types, specifically value/quality pairs. While some Adapters currently support geolocation and coordinate complex data types, they do not all support value/quality data types. In industr...
Derek Wong over 1 year ago in AVEVA™ Adapters / General 0 No status

AVEVA Adapter for MQTT to support payload compression from the source MQTT SparkplugB device

AVEVA Adapter for MQTT (SparkplugB data source) to support payload compression from the source MQTT SparkplugB device. Compression can be enabled at the Edge, for example Enable compression and/or aliasing at the Edge: For compression, either the ...
Ee Sheing Lee 3 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 1 No status

Make Analysis trigger on different inputs when timestamps of input tags are equal

If an Analysis is triggered on "Any Input", and the inputs have the same timestamp but come in after each other, the Analysis is only triggered at the first input. For example: We have a simple Analysis which summarizes 2 tag. The first tag comes...
ArieVanBoven almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 11 Evaluating

Improve Asset Analytics Data Cache performance to handle large scale changes

There is a considerable amount of downtime in our system (20+ minutes) when a template change is performed. The root cause is a limitation on how the analysis service handles the removal of AF Attributes from the Data Cache. Due to this limitation...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 Evaluating

Allow approval groups in RtReports to approve in any order (parallel approvals) instead of requiring a sequential approval hierarchy.

Currently, RtReports processes approval groups sequentially. For example, if a report requires approvals from both Group 1 and Group 2, Group 1 must complete its approval before Group 2 is able to review and approve the report. The option to confi...
Guest 22 days ago in AVEVA™ RtReports / General 0 No status

More functions to support operations on arrays

The arrays in Expression and Event Frame Generation analyses are useful, but use cases are emerging where more functions are needed to reduce/calculate the arrays in more streamlined fashion. For example, Concat function should support array of ch...
Guest almost 4 years ago in AVEVA™ PI Server / Analytics & Calculations 19 No status

Enable AVEVA Adapter for OPC UA to detect unchanged source values beyond a configured interval and continue sending the last known value with refreshed timestamps until a new source event is received

This enhancement is required so the AVEVA Adapter for OPC UA can functionally match ABB 800xA / Vtrin RTDB historical behavior while preserving existing PI System and Asset Framework functionality. The customer would like this capability implement...
Claudia Sischin 3 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest almost 4 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status