To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support SAML authentication

The PI Integrator for Esri ArcGIS does not support SAML authentication through Portal. Support for SAML authentication would allow PI Integrator users to configure their own Identity Provider.
Guest about 4 years ago in PI Integrators / PI Integrator for Esri ArcGIS 2 No status

Allow attribute annotations to be published with the Integrator

I want to publish the attribute annotation for a time series event using the Integrator. For example, if a user enters data in PI Manual Logger, they enter comments as annotations to the tag event. I would like to publish those annotations along w...
Guest about 4 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 3 No status

Allow default value for rollup analysis

Allow a default value to be specified for rollup analysis. This value would be used when the rollup cannot find any matching attributes, thereby eliminating a lot of rollup analysis errors and Calc Failed values from being written.
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 7 No status

Reason Code value to AF element attribute or PI Tag

As a PI system user, I need the ability to use reason codes to develop reports and dashboards. The current functionality of PI Vision symbols and analytics do not really enable the use of the current data type of EF attribute. The ability to map ...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Allow binding of a custom SSL certificate after installation of PI Integrator for Esri ArcGIS

As an administrator for the PI Integrator for Esri ArcGIS 2017, I want to be able to change the SSL certificate bound to the application through an installer wizard. Currently, the only option is to uninstall and reinstall the application, or manu...
Guest about 4 years ago in PI Integrators / PI Integrator for Esri ArcGIS 2 No status

Option to not capture value for event frames generation

As an engineer I need the option to not capture values for event frames generation so that if I have out-of-order events, I don't have to recapture the values. Note: This was previously Enhancement 114349.
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 1 Declined

Add a function to calculate the week number of the year

In order to calculate the current shift operating at a plant, I need to calculate where in the 28-day cycle the current week is. Knowing which week of the year it is allows me to do that. Note that current PI weekday functions always count Sunday ...
Guest about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 4 Declined

Automatically add new attributes to existing views

As a PI administrator I want the integrator to detect new attributes on a template and add them to existing views automatically. This would be easier than creating a new view and asking users to reference this new output.
Guest about 4 years ago in PI Integrators / General 3 Declined

Allow PI Integrator to create a new file per publication in Amazon S3

As a PI Integrator user, I'd like PI Integrator to create a new file per publication in Amazon S3. Currently there is a workaround with Maximum Rows/Objects option in target configuration, but it is not straightforward and cumbersome.
Guest about 4 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 2 No status

Allow BadVal to check multiple inputs or IFERROR

Right now BadVal can only check one variable or Expression.  So if I am evaluating an expression with say 10 inputs, and I want the expression to output NoOutput() if any one of the 10 inputs are BadVal, then I have 2 options right now. ...
taterhead247 about 4 years ago in AVEVA™ PI Server / Analytics & Calculations 5 No status