Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Support Kerberos for adapters on Linux

Adapters are supported on Ubuntu, which also provides support for Kerberos (https://documentation.ubuntu.com/server/explanation/intro-to/kerberos/) Adding Kerberos support would increase the options for deploying adapters securely.
Mike Horrocks about 1 year ago in AVEVA™ Adapters / General 0 No status

Adapter for OPC UA to support Global Discovery Server

Currently, to manage the OPC UA Server/Adapter certificate, we have to manually move the certificate or get the certificate trusted beforehand. This is expected for self signed Application certificate for both the Server and the Client (Adapter). ...
Ee Sheing Lee about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 2 Tell us more

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan about 3 years ago in AVEVA™ Adapters / New Connectivity 0 No status

Parametrize the "True for x minutes" parameter in event frame analysis

It would be nice if we could reference an attribute or analysis variable to provide the value for the "True for 'x' minutes" parameter, rather than having to hard-code this value. This would be especially helpful in cases where we have numerous el...
Gregory Malek almost 2 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

Multiple Event Frames generation

I want the ability to have simultainiously events generated from the same analyses. The way now is that a event frame must be closed before a new event is generated.
Hobbe about 4 years ago in AVEVA™ PI Server / Event Frames (EF) 3 Declined

Export Event Frame Analysis Reference

The AF XML Import/Export is described by OSIsoft as a tool for backing up and restoring an AF database to either the same server or a different server. However, one object relationship that is not included in the XML file is an Event Frame's refer...
Guest about 4 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

To have a ‘second’ Reason column available

It would be great to use Event Frames to classify and afterwards be able to do Equipment Downtime root cause analysis. We’re using Reason codes on the predefined field, however it would be great to have a second available Code Editors than “Reason...
mmoiron about 4 years ago in AVEVA™ PI Server / Event Frames (EF) 1 No status

Include information from Json body in the stream name created by the MQTT Adapter

As a system admin I would like to send mqtt messages from multiple devices to a single topic on an mqtt broker. Each message would contain data for the device along with a field to say which device the data has come from. Then I would like to use ...
Guest about 4 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

Stream-level debugging

As a PI System Administrator, I'd like to be able to trace values being received, and subsequently being sent by the Adapter, similar to PI Interfaces. Having the ability to trace/log timestamps and values for specific streams would greatly help ...
Guest about 4 years ago in AVEVA™ Adapters / General 0 Future consideration