To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 181 of 5213

Analysis service should include functionality for limiting an Event Frame to x time after the start trigger.

Timely notification of shutdowns is critical for managing remote unmanned equipment. Control modules outputs may only indicate a fault condition and require and operator to reset locally. Detailed information on the fault condition can be obtained...
kurthopf over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

RTReport Show Event Frames Between Time Frame

The ability to see all event frames for a specified range in a time-based report. Currently, RtReports doesn't have any capability to list existing Event Frames, whether from specific elements or by any criteria and the only Event Frame reporting...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

PI Interface for Emerson DeltaV Syncade Batch - Allow EF creation for Phase Step and Phase State level

Users would like to have the option to create event frames at the Phase Step or Phase State level using the PI Interface for Emerson DeltaV Syncade Batch. From the Live Library documentation for PI Interface for Emerson DeltaV Syncade Batch (Emer...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Download PI Event Frames Interface Manager by itself

It is not possible to download just the PI Event Frames Interface Manager. Request to download PI Event Frames Interface Manager by itself similar to how PI ICU is treated. This would allow users to obtain bug fixes in the PI Event Frames Interfac...
Guest over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

Allow the BACnet Adapter to handle responses with an LVT that does not match the request

Currently the BACnet Adapter expects devices to respond with the same "Length Value, and Type" (LVT) value as the request. When this occurs the BACnet Adapter cannot parse the data in the response. For example: Request from Adapter, LVT=1 Response...
Nico Cha almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for BACnet 0 No status

Addition of substitution parameters in DefaultStreamIdPattern -> specify a ValueField for it to read from

People wanting to use a single EventHub and Container holding events from many sources with common attribute naming. Want to be able to differentiate the naming of the pi tags based on source. Being able to substitute a unique source identifier (s...
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status

Error message should be generated for the Modbus request time out

After request time out, Modbus adapter should generate an error as time out after specified duration set by user.
Guest almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Add the option "Ignore Bad_WaitingForInitialData Status"

In the connectors there was the option "Ignore Bad_WaitingForInitialData Status", as described here. For gen 1 there was a need to edit the config files directly, and in gen 2 the option was integrated into the UI. Instead for the adapter I recent...
sahilp about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Use a PI tag with point type timestamp as the retrieval method on an EF attribute.

Allow the ability to collect data at specific key points within an EF. Timestamps can be saved to a PI tag via a separate analysis or to an EF via an output variable then used with the Exact Time retrieval method instead of using a relative time.