Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 452 of 5194

Need to start/stop individual data sources

When going in the PI Connector Admin page in the data sources page, we cannot start/stop individual data sources listed when there is more than one. To stop one you need to stop all the data sources listed.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Give the ability upload different Tag Naming files in DCM / OPC UA Connector

When uploading a "Tag Naming" file in DCM, this file completly replace the existing Tag naming. It mean that a Tag naming file must be done for all datasources within one connector. It would be a lot more easy when dealing with a large number of t...
Fred_EYRAUD over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

Allow sending data to the OPC UA Server

Currently the Interface is supporting read only. Sending data is also required
meierke1 over 3 years ago in PI Connectors / PI Connector for OPC UA 4 Declined

PI OPC UA Connector - point attribute based configuration

We are just starting the first tests with PI OPC UA Interface. We notice that the classic method of tag configuration, known from the interface, is no longer possible. This is probably due to the connector concept. Unfortunately, this does not fit...
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add additional Analysis Search Criteria options to PSE Management

It would be helpful if you could search by Element Category or Element Description when searching for Analyses in PSE. My setup is 5 templates (CHW, Water, HW, Electric, Steam), each of which have accounts that can come from 5 different sources (s...
Kelsey Bobeck over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Increase the sub seconds to be more that 3 decimal places in PSE UI

We faced an issue with thinking the formula DR time series data in PI System Explorer was duplicating results but that was because the sub seconds were not showing and there were difference in the sub seconds for the two results which we thought w...
Sakina AlHamood over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Option to paste column names to AF table definition

Option to Paste column names in table definition. In the moment everything has to be put manually. Also sorting is painful. If we could just copy an array/list from Excel and paste here it would make the handling a lot easier. (Copying the table d...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status