Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 777 of 5194

Root NodeID 255 character limit

For the PI Connector OPC UA configuration, the Root NodeIds field can only accept a maximum of 255 characters currently. This is seriously limiting if we need to gather a lot of data from many pieces of equipment
Guest over 3 years ago in PI Connectors / New PI Connector Request 1 No status

Create a PI connector/interface for devices communicating using the BACnet/SC protocol

The instance of the PI system that the group I work in is over 50% complete in integrating the JCI Metasys building control systems from 190 facilities. The software/firmware of the devices that comprise the JCI Metasys system we are using current...
Daniel Chiariello over 1 year ago in PI Connectors / PI System Connector 0 No status

Increase assembly description character limit for AF Plugins

Currently when inserting an AF plugin via RegPlugin64.exe , there is a 1000 character hard limit for the AssemblyDescription parameter that the AF plugin has in its AssemblyInfo.cs class. It has been found that some plugins have more than 1000 cha...
Guest about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Flexibility in configuring the DescriptionField tag (<DescriptionField value="TEXT"/>)

PI-Connector-for-GE-e-terrahabitat-1.1.1.42 Currently, the Connector for e-terrahabitat only allows the configuration of the Description Field to return only data from the TEXT field and PNTNAM table. The configuration of the Description field nee...
Guest 9 months ago in PI Connectors / Other specific PI Connector 0 No status

Expand/Collapse All Child Elements

A good feature on the PI System Explorer would be to be able to expand/collapse all child elements by right clicking on the parent element. Also, being able to reevaluate the names for multiple child elements at once rather than having to click on...
Guest 9 months ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Prevent Analysis calc failure for attribute not found

If the same analysis is trying to be used for multiple templates, there will be times when some attributes are not available from a template - this will cause the analysis to fail. Even when the difference in attributes is known and attempted to b...
Dan Benedict over 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Automatically updating digital state sets with PI System Connector

Add a feature to the PI System Connector so that it updates automatically digital state sets on the Destination Data Archive when edited on the source Data Archive. Currently PI System Connector replicates digital state sets referenced by the PI p...
Guest over 2 years ago in PI Connectors / PI System Connector 0 No status

Support synchronizing multiple AF databases with PI System Connector

A customer needs to replicate the data and AF models from a secured PI Server to a second PI Server on the business network. The PI Server has 3 or 4 AF databases because the AF models are segregated by function. Currently the PI System Connector ...
Laurie Dieffenbach over 2 years ago in PI Connectors / PI System Connector 0 No status

Use digital states in AF instead of Enumeration sets

A customer thinks it is unreasonable to require all customers to recreate the linkage of a new attribute to a Enumeration Set that is a copy of the Digital State Set for the attribute’s linked PI tag. There should really be an Attribute “Value Typ...
Audrey Finken about 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PI System Connector should be able to Parameterize AF objects (like attributes) to dynamically update between environments

In Asset Framework, we are able to use substitution parameters to define PI Point Data References because the variable is able to resolve based on the template. PI System Connector is used to synchronize, and keep perfect copies of the assets betw...
zachary cmelak 10 months ago in PI Connectors / PI System Connector 0 No status