Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 504 of 5258

Allow Select All of search results with filter criteria (very simple GUI change)

When performing a search in PI System Explorer, you can perform a "Select All" on the search results by left clicking on an empty gray section at the top. This section disappears after applying filter criteria, effectively removing the "Select All...
Greg Malek about 1 month ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Automated discovery on a schedule

Enable Regular Discovery: While not continuous by default, discovery can be scripted or scheduled to run periodically for dynamic environments include this as a feature, so that automatic discovery and automatic addition of new discoveries can be ...
Nick Ciampa about 1 month ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Copy paste issue for child attributes

On PI System explorer when you copy an attribute with child attributes, only the first child attribute get's copied as well and the rest is missing. This was working with PI System Explorer 2016 R2 SP1 whereas it does not with Version 2018 SP3 pat...
PhilippEven over 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

OPC UA Adapter Create Tag on Discovery

For the OPC UA Adapter, we are noticing that a tag won't be created until a data point comes in after the tag is added to the data filter. That causes issues for slow updating tags. For instance an open/shut valve that is rarely operated. We have ...
Damon Vinciguerra 7 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Future consideration

Add an option to disable endpoint validation between results of GetEndpoints and CreateSession

As discussed in OPC UA Adapter - Mismatch of Endpoints returned by GetEndpoints and CreateSession , in the OPC UA SDK 4.1.0+ endpoint validation was added to compare results returned in responses to GetEndpoints and CreateSession requests. The OPC...
Andrew Miu 8 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 Planned

Be able to sort Elements and be displayed in ways other than alphabetically.

We have seen several instances where we would like to have the order of element displayed in AF/Vision be sorted by process order, not alphabetically.  Suggest adding a "sort" field and an option to have element arranged by that rather than a...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 9 Declined

PI AF Template Versioning

Allow for PI AF templates to be version controlled. Include the ability to revert to previous template version, or continue to use old versions for specific elements. This will reduce the risk of deployment and improve change/release management pr...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

Allow PI Adapter for MQTT (Generic) to process non-json payloads

Some MQTT devices do not send json payloads; for example, some devices send a single value as the payload for a specific topic. It would be beneficial for the adapter to be able to handle this rather than to convert these payloads into json befo...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 3 In development

Allow client-level failover on a per data source component level

Currently the client-level failover for Adapters occur on a per Adapter level. Which means that for instances where multiple data sources are configured, in some circumstances failover may result in an instance with a bad connection to a particula...
Miwa Teranishi 11 months ago in AVEVA™ Adapters / General 0 No status

Allow AVEVA Adapter for Modbus TCP to collect data on INT64 and UINT64 registers

Certain equipment is providing energy data under INT64 or UNIT64 register types. However, the Adapter currently only supports FLOAT64, which is not compatible. We want to be able to configure the Adapter for Modbus TCP to collect data on INT64 and...
Alexa Derago 5 months ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 Future consideration