Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 710 of 5192

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Enhance the OPC DA interface to avoid mixing polled and advise tags on the same scan class

The interface does not log any informational messages about polled and advise tags getting mixed up on a scan class. Currently it would detect that polled tags are part of scan class 1 and reject it and print the following: E 13-Apr-16 17:26:18 ...
Guest over 3 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

SNMP Interface to support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.

SNMP Interface should support using multiple types of encryption such as DES, 3DES, and AES-128 bit, AES-192 bit, and AES-256 bit.
Guest over 3 years ago in PI Interfaces / General 0 No status

Add additional Analysis Search Criteria options to PSE Management

It would be helpful if you could search by Element Category or Element Description when searching for Analyses in PSE. My setup is 5 templates (CHW, Water, HW, Electric, Steam), each of which have accounts that can come from 5 different sources (s...
Kelsey Bobeck over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Increase the sub seconds to be more that 3 decimal places in PSE UI

We faced an issue with thinking the formula DR time series data in PI System Explorer was duplicating results but that was because the sub seconds were not showing and there were difference in the sub seconds for the two results which we thought w...
Sakina AlHamood over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Option to paste column names to AF table definition

Option to Paste column names in table definition. In the moment everything has to be put manually. Also sorting is painful. If we could just copy an array/list from Excel and paste here it would make the handling a lot easier. (Copying the table d...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Store an OPC Server's "VT_EMPTY" Data Type as a "Bad" in PI Data Archive

When there is a problem within an OPC Server, some Items receives "VT_EMPTY" data type values. PI OPC DA Interface ignores this information, and in PI Data Archive present to users and applications the last valid value - that might be incorrect.
jmalmeida 8 months ago in PI Interfaces / PI Interface for OPC DA 0 No status