Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 890 of 5276

backfilling start date error

I have one specific complaint but when I’m creating/testing a new event frame it is the worst. When backfilling a single analysis, the start time and end time boxes will throw an error and not allow the you to start the backfill if at any time the...
David Lopert about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PI System Connector: Allow subset of event frames to be replicated

Currently you only have the ability to replicate ALL event frames and only if you want to replicate the entire AF database. We have one main AF database with many different types of event frames; however we do not want to replicate them all. It wo...
Rebekah_Wilson about 2 years ago in PI Connectors / PI System Connector 1 No status

Properly configure allowed Analytic / Notification host during upgrade

When upgrading Analytics or Notifications, the installer forcefully changes the allowed host parameter in the Configuration database for the application being installed. This should not happen. There should be an additional CLI parameter (and coun...
Tyler Engelhardt about 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Provide alternative message to 'No value defined"

When querying AF Element Information certain values display: "No value defined." and customer reaction was that there was something not working correctly/error that needed to be investigated. Suggestion was to change text to either show the value ...
Guest about 2 years ago in PI to CONNECT / General 0 No status

Native Python connector for Linux

I'm a Lead Data Scientist. I've built the MLOps pipeline for Machine Learning (ML) models. To train a model, I need at least 2-3 years of data at high frequency. While the entire data sciences community relies heavily on Python, I'm amazed to see ...
Guest about 1 year ago in PI Connectors / New PI Connector Request 0 No status

Utilisting exisiting PI Datalink functions within Asset Framework for attributes

PI AF attributes (used for analyses) lacks the ability to filter for conditional values. (e.g. the function PIAdvCalcFilVal). Often data can be represented poorly for calculations and there isnt an easy way to filter the outliers and use that valu...
Mitchell Davidson over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

PI Connectors/Relay/DCM be able to use GMSA accounts

When installing any PI Connector / Relay / Data Collection Manager, I am unable to use a GMSA account as part of the install. I'm able to go change the service afterwards but the service account requires a password in the installer (which there is...
kevin.brashears over 2 years ago in PI Connectors / Installation 0 No status

Event Frame Search using Attribute Value Filter should return results if the Attribute contains the specified value anytime during the duration of the Event Frame.

When specifying an Attribute Value Filter, PI System Explorer's Event Frame Search should return any Event Frame where the attribute has an event with the specified value during the duration of the event frame. Currently, the search only return...
Bethany Jewett over 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 2 No status

Need EtherNet/IP connector to be able to read and write.

Need EtherNet/IP connector to be able to read and write. Currently EtherNet/IP connector is read only.
Francis2 over 3 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Wonderware Historian Connector - Allow Custom Tag Naming

The Wonderware/AVEVA Historian has some different illegal characters than PI tags and there are also cases where a single tag prefix isn't sufficient (e.g. when storing data from multiple buildings in the WW Historian). The Connector should have t...
Sublette-Sanofi over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status