To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 496 of 5213
486 VOTE

Ability to search for PI Points used by PI AF attributes

As a user, I want to be able to search for specific PI Points used by PI AF attributes, so that I can easily find where the PI Points are being used.
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 37 Evaluating

The DNP3 Adapter should support group 40

The interface supports this group. The Adapter does not (see https://docs.aveva.com/bundle/adapter-for-dnp3/page/1231146.html). It is essential that the Adapter have this identical feature as the interface, to allow it to read the same data and be...
Daniel Lopez 4 days ago in AVEVA™ Adapters / AVEVA Adapter for DNP3 0 No status

Start/stop components to be retained on restart

Currently it is possible to stop a component for a running adapter. However, if the adapter is restarted the component will automatically start up. It would allow for extra control during commissioning, downtime, incidents, etc. to be able to disa...
Mike Horrocks 26 days ago in AVEVA™ Adapters / General 0 No status

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 10 days ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status
219 VOTE

Allow substitution parameters to be used in the SELECT and FROM clauses of the TableLookup Data Reference

As a user, I would like TableLookup Data Reference to be able to use substitution parameters to specify the column name(s) and table name for the SELECT and FROM fields respectively. This would allow for the use of attribute values like those from...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 17 No status
198 VOTE

Add more advanced string handling functions to the String Builder data reference

I would like to use some more advanced string functions such as Split, Len (string length), and even regex filtering to allow more fine grained control of how some input strings (such as attribute values or substitution parameters) are manipulated...
John Messinger over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 29 No status
160 VOTE

Attribute UOM Substitution Parameter

If you have a PI Point attribute with auto tag creation and you want the attribute UOM and PI Point engunits to match, you have to define it twice; once in the attribute UOM field and a second in the attribute configuration string, e.g. engunits=m...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 21 No status

SharePoint or file folder link for Documentation purposes.

Within AF Element General tab. It would be great to have an option to link some kind of documentation file path that describes the element in detail. This would allow the admin or any user to find the complete documentation on that particular Meta...
Martin Kocak 9 days ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status
108 VOTE

Easily deploying and maintaining AF objects in multiple remote AF databases

Originally posted on PI Square at https://pisquare.osisoft.com/ideas/5538-easily-deploying-and-maintaining-af-objects-in-multiple-remote-af-databases Today, one of the method that can be used to selectively reconcile object changes (including tem...
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 14 No status
102 VOTE

PI Adapter for OPC UA should be able to write outputs to the OPC UA Server

The PI Adapter should be able to create a data pipe listener on certain streams (unsolicited reads) that would trigger the writes back to the OPC UA Server. This is useful when providing set points to the equipment without the need of establishin...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 9 No status