To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 156 of 5194

Add new PIPointAttribute for "StaleTimeout"

While no customers have asked for this directly, I have seen many customers ask how to check a tag for being stale. The solution to date assumes all tags have the same staleness timeout, which really is not the case most of the time. This new "St...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Provide a scaling option to set a value for either min or max while having the other as automatic based on plotted value range.

This was useful and available in ProcessBook but not supported in PIVision. Trends can be quite messy to read and potentially misleading without this feature especially with many tags plotted and some having very small scales etc. There is a worka...
Ajish Varghese over 1 year ago in AVEVA™ PI Vision™ / ProcessBook Migration 1 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 4 No status

Provide more granular configuration for default ACLs

As a PI Administrator of a PI System with complex security requirements, I need to set up different default permissions for various users so they can create tags that automatically have the proper security instead of having to rely on a process/pr...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 No status

Support User Information in Connection History Tool

(pidiag -connectionhistory) Support the collection and retrieval of PI / Windows user information by the connection history database.   Currently, the connection history database only stores IP addresses which can be misleading when m...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Force Shift warning is misleading

When force shifting an archive, the following message is displayed: "Warning: This shift will clear data from the target archive. Are you sure you want to force an archive shift on to a new archive?" When Auto Archive Creation is enabled (having...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Make it easier to get a list of buffered or unbuffered points on the PI Data Archive

For PI System Administrators, it would be nice to be able to easily get a list of all buffered or unbuffered points on the PI Data Archive. Currently, a list of buffered points is possible to retrieve using 'piartool -bfs -ptlist', but a comprehe...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Integrate with Excel Tables (Using PI Datalink) into PI Vision

Previously processbook had the ability to display excel files/tables within a display. This was particularly handy due to the customisation of the formulas and increased control of the calculations and how each column & row was generated. I th...
Mitchell Davidson about 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status

Incremental backups are not possible because of frequent backfilling

Occasional back filling of data would cause 5 TB of archives to be backed up with incremental backups. This is frustrating because only a few KB of data is changed in each archive. Can OSIsoft provide a way to backup only the data that has changed...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Provide automation for(especially migrated) displays

As large numbers of displays are being migrated into PI Vision (from PI ProcessBook), it would be very useful to allow scripting of the process for things like determining the imported file structure, keywords and display ownership.
Laurie Dieffenbach about 3 years ago in AVEVA™ PI Vision™ / ProcessBook Migration 0 No status