To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 222 of 5194

As a PI Administrator, we should be able to see which PI mapping was used for a Windows AD user in PI message logs.

Through PI message logs I want to see which PI mapping was used for a Windows AD user, currently only the PI identity associated the windows AD is visible in the Logs. PI mapping information will give us more idea/facts about the particular Window...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Allow bi-temporal data archiving

PI DA Server should allow for more flexibility in terms of the format of archived data. A big advantage would be if PI could archive two timestamps per event. One timestamp will come from whatever the data source is (PI Interfaces, fiels devices, ...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 Declined

Thresholds for PI Points

It would be nice to have threshold attributes for pi points. Then we could configure that values received from the source outside this limits would be ignored (not stored), substituted by the respective threshold value or even by an "Over\Under Ra...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 2 Declined

Event mode that applies NoReplace to snapshot as well

Currently the NoReplace event mode will Append data if a value with the same timestamp as the snapshot comes in. Customer would like an event mode that would discard the value if there is existing data with the same timestamp regardless of the val...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

Method to backup and restore PI Points only

The PI backup tools currently do not have a method to backup only the files related to PI Points. The purpose of this would be to refresh the point table on a QA system from a production system. The current PI backup method is all or nothing.
GaryYegiazaryan over 3 years ago in AVEVA™ PI Server / Data Archive 0 No status

Negative numbers in digitalsets

Negative numbers in digitalsets for all PI interface and skip numbers, basically that the digitalset is like the enum of AF
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 1 No status

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Add a Trace Route feature to PI Ping interface

Add ping -i feature to the interface and allow for either the output of the ping time or destination in the PI tag. Case: This will allow for IT to monitor the network path taken in communication from one site to another. If the route has change...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server

ICU> When the ISU instance is removed for a server, other interfaces were not properly detecting that and were behaving as though there was still an ISU instance for that server. There are documented known issues related to the slow ICU loading...
Guest 12 months ago in PI Interfaces / Other Interfaces 0 No status

PI Server should recover from any ungraceful shutdown

While the recovery mechanism for queue corruption is much more robust on newer version of PI Data Archive compared to previous versions, there are still few cases where PI Data Archive does not fully recover from ungraceful shutdowns. PI Server sh...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 0 Declined