Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 248 of 5257

Enable OmfEgress component to be configurable by instance (by component)

In our process we wish to send a different set of data to different PI environments. For instance we would like all data to egress to the PROD environment while only egress a subset of data to the DEV environment, in which we don't need all the da...
Guest over 3 years ago in AVEVA™ Adapters / General 7 Future consideration

Adapter should have the ability to read from a TCP Socket

In a lighthouse project we needed to read from a TCP Socket. Ideally the Adapter for Structured Data files would be able to read from a socket and process its data.
Fabio Dani 3 months ago in AVEVA™ Adapters / AVEVA Adapter for Structured Data Files 1 No status

Queue PI Point creation attempts if made during archive shifts

Currently, when archives are shifting, any attempts to create PI Points will be rejected with the error "Error on internal point editing call during point create for archive add point(<point info>). [-11095] Archive Shift already in progress...
Ryan Biggins 10 months ago in AVEVA™ PI Server / Data Archive 0 No status

Rename overwritten archive files with new start time when using Archive_OverwriteDataOnAutoShiftFailure

When using the Tuning Parameter, "Archive_OverwriteDataOnAutoShiftFailure", the system uses the oldest registered archive as the new primary. But it keeps the name of the old archive. It would be very helpful if the archive subsystem could rename ...
kliffhopson 5 months ago in AVEVA™ PI Server / Data Archive 0 No status

Add new PIPointAttribute for "StaleTimeout"

While no customers have asked for this directly, I have seen many customers ask how to check a tag for being stale. The solution to date assumes all tags have the same staleness timeout, which really is not the case most of the time. This new "St...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 3 No status

Support outputs/write data from PI Adapters

No description provided
Allison Muraski over 3 years ago in AVEVA™ Adapters / General 4 No status

Sampling/Publishing Interval parameters to be part of Data Selection description

When configuring the AVEVA Adapters in general, we would find more convenient to be able to define the ‘Sampling Interval’ and 'Publishing Interval' parameters inside the ‘Data Selection’ configuration per each data stream. For instance, when desc...
Christian Leroux almost 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Please add a feature for the OPC UA adapter to enable the adapter to only store values with a good status or rather filtering out bad values

When receiving bad values from the OPC UA Server to the adapter there is no option to filter out bad values. So these values get stored in the Data Archive and are causing problems with analyses (e.g. expression or Event Frame generation). At the ...
Timur Eroglu almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

Add point Type INT64, UINT64, to PI Archive

Some interfaces such as PI Modbus allow the polling of a 64-bit signed integer value or a 64-bit unsigned integer value. Yet the database does not allow you to store these values in their native formats. You must store them as a 64-bit floating po...
Guest over 3 years ago in AVEVA™ PI Server / Data Archive 4 No status

PI Adapter for AspenTech IP21

We have customers who are using AspenTech IP 21 and would like to have data replicated in both PI DataArchive and OCS in the future. Since the PI Interface is a bit outdated, a new PI Adapter would make perfect sense (since there is already a PI C...
Guest over 3 years ago in AVEVA™ Adapters / New Connectivity 4 Tell us more