To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 290 of 5192

Support two-way TLS/SSL authentication to Confluent Schema Registry

As a PI Integrator user, I would like to be able to configure the PI Integrator for Business Analytics to add a Confluent Schema Registry that requires two-way TLS authentication. Currently there is nowhere in the PI Integrator UI to configure a c...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Use of X.509 CA Certificate for authentication to Azure IoT Hub

I am evaluating the use of PI Integrator for Business - Advanced Edition for integration with an Azure IoT Hub. Based on the documentation, authentication is only supported via a symmetric key. Are there any plans to update the PI integrator to us...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 1 No status

Re-importing a schema from a file should not clear out all fields.

Currently, the PI Integrator for Business Analytics UI clears all fields each time a schema file is imported. I would like to be able to make edits to an existing imported schema without needing to edit each schema property/attribute.
Bethany Jewett almost 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Add Indexes to SQL targets for better performance

The Integrator continually performs SELECT statements on the target table, which can take an extremely long time as the table continues to grow. Indexes are needed on the table created by the Integrator in order to keep performance acceptable.
jcox almost 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Enable the configuration for VPC Endpoint when publishing a view to AWS S3

We have observed that, while the S3 Writer verification page goes through the VPC gateway/endpoint, the View publish page bypasses the VPC gateway/endpoint and uses the internet. The PI Integrator for BA does not currently establish a communicatio...
Guest almost 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Expand Healthpoint (Device Status) Information of the PI Adapter for Modbus TCP from Component to "Device" Level

When configuring PI Modbus TCP adapter you first define a component level and under this type you define your different devices/machines/sensors. In case of a broken connection to one of the devices the healthpoints currently only deliver the stat...
Mario Amrhein about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Support ArcGIS since the PI ESRI Integrator has been retired.

As a customer that used to utilize the PI ESRI Integrator and it is no longer supported we were forced to disable the interface when we found a cyber security vulnerability. The AVEVA recommended replacement is PI4BA. The only supported common int...
Robert Lane about 2 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Support for "RTU over TCP" for Modbus Adapter using MBAP header

Challenge: Today, the PI Adapter for Modbus TCP does not natively support " RTU over TCP". It does support Modbus TCP, so as long as the "bridge" properly converts Modbus RTU to Modbus TCP (including the MBAP header), it should work fine. If the b...
Hans-Otto Weinhold about 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Modbus TCP 0 No status

Provide more information on why logon failed

When using PI Integrator for esri ArcGIS, logon to Enterprise portal or AGOL can fail. But the current UI does not provide why it failed. As a user, I would like to know why my portal/AGOL login have failed so that I can either use alternate accou...
Jinmo Yi over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status

Support ESRI ArcGIS 10.8.1

Please update testing to include support for ESRI Arc GIS 10.8.1 which was released in July 2020
Guest over 3 years ago in PI Integrators / PI Integrator for Esri ArcGIS 0 No status