Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Possibility to use array values in analysis

I would like to use array attribute values in analytics. For example, I have the coefficients of a polynomial curve stored in an array and I would like to use this to calculate que Producible Power of a WTG. Storing this kind of data in separate a...
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 Declined

More Standard Symbols - Heatmap, Countours, Stacked bar chart with time

Hi Want more, instead of using Excel. Regards Ulf Kristian Sandvik
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 1 No status

Enable TLS Configuration

As a customer I want HTTP and HTTPS support for Edge DS so that I can configure the appropriate level of transport security for my deployment
Guest about 4 years ago in Edge Data Store / General 2 Declined

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 11 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Remove arbitrary distinctions between AF points and PI points

Currently, Expressions like TimeGE which require two time contexts to evaluate only work with PI points, and not AF points. This restriction is arbitrary and does not appear to be documented anywhere. Unless documented, this should be regarded as ...
Kevin Wood 12 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Provide GUI for Configuration

Edge Data Store would require a GUI for configuration and health status to work more efficiently to set it up with too many efforts. The GUI should allow to set up the connection to the Data sources of the included PI Adapters, provide OPC UA brow...
Guest over 2 years ago in Edge Data Store / General 1 No status

Add the function/calcultion of "Moving Average" for PI Tags

The ability to create an average calculation is within PI Vision, but it doesnt do moving average. You can set custom timing intervals (eg. every 5 min etc.) but what about a 5 min moving average that has a continuou data points for a trend. A wor...
Mitchell Davidson almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Make PI Vision Calculation not affected by PI Point or AF Attribute renaming

When a PI point is renamed, any symbols that reference it directly continue to work. However, calculations that depend on the renamed PI point stop functioning. Please update the calculations so they remain functional even after PI points or AF at...
marc.cote 7 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Possible to use a Calculated variable into a new Calculated value like a "Tag"

No description provided
Guest almost 4 years ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

EDS: OPC DA Connector

Ability for OPC DA connector to write data to Edge Data Store.
Guest about 4 years ago in Edge Data Store / Ingress 1 Declined