Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 134 of 5209

Add parameter "Max Monitored Items per Subscription"

The connector for OPC UA includes a parameter “Max Monitored Items per Subscription”, which is very helpful in managing UA servers which may have limits on the maximum items per subscription. This parameter needs to also be available in the adapters.
sahilp 11 months ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 3 Future consideration

displayname/localname for identifier that excludes namespace and data type

Example: OPC UA Server 'Name': 2.0:W-HVAC-AC-1-IO!Wtot Namespace: 2 Datatype: 0 Identifier: W-HVAC-AC-1-IO!Wtot OPC UA Server 'DisplayName': W-HVAC-AC-1-IO!Wtot OPC UA Adapter {Identifier} returns: 2.0:W-HVAC-AC-1-IO!Wtot Required stream name: W-H...
Guest over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Enable Adapter for OPC UA to use the Pub/Sub method

Pub/Sub is proposed to be a more efficient and scalable method of transferring data using OPC UA. Allowing the adapter to access data in this way would increase the options for data collection, and allow the OPC UA adapter to be used in many more ...
Mike Horrocks over 1 year ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 0 No status

Support System States for the Adapter for Azure Event Hubs

The data passed through the Adapter for Azure Event Hubs can be very dynamic in its configuration. It would be useful to be able to send system states to indicate bad data, and possibly the nature of that bad data. In the same way that interfaces ...
Mike Horrocks almost 2 years ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 2 No status

Allow following articles to see when it is validated or has been updated

Need to ability to subscribe for updates to the article for when a fix has been found/validated - get notifications on bug status, as well as any available workarounds. This is especially important for non-validated articles
Gabriel Verreault over 3 years ago in Customer Portal & PI Square / Knowledge Base 0 No status

PI Adapter for GE e-terrahabitat/HabConnect

We need a new robust product to support data transfer between GE e-terrahabitat/HabConnect and PI. This product would need to support the following: Highly available remote management/deployment multiple instances on a single node (to support larg...
GaryYegiazaryan over 2 years ago in AVEVA™ Adapters / New Connectivity 0 No status

PI Adapter for OPC UA should send the previous value when it has been with the same value for a long time

"This enhancement request proposes a solution to address the issue of data interpolation between two values far apart in time in adapter data collection. The suggestion is to include the value right before the new data point, ensuring the fidelity...
Fabio Dani over 2 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 1 No status

More control on MQTT parameters on the AVEVA Adapter for MQTT

It would be nice to have more control on additional MQTT parameters for the AVEVA Adapter for MQTT. We are especially interested in having control on the QoS of the subscription. Setting this would give us more control in buffering, especially whe...
Tombayu Hidayat 12 months ago in AVEVA™ Adapters / AVEVA Adapter for MQTT 0 No status

API to check Adapter buffer statistics

We can check buffer statistics with PI Buffer subsystem (pibufss -cfg, qs) and also with PI Connector/Relay, to verify whether Buffer is healthy, events in queue and etc.Adapter does not has any API to check this.
Ee Sheing Lee about 2 years ago in AVEVA™ Adapters / General 0 No status

Defining "Scan Class" and "Poll" Capabilities in Aveva Adapter for Azure Event Hubs

Define the "Scan Class" and "Poll" capabilities in the Aveva Adapter for Azure Event Hubs, similar to the functionality available in the Interface. Ensure the ability to manually select a "Scan Class" for PI Points and define it as "Poll".
Guest about 1 year ago in AVEVA™ Adapters / AVEVA Adapter for Azure Event Hubs 0 No status