Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Interfaces

Showing 330 of 5209

DeltaV Smart Connector configurability

Smart Connector foo DeltaV should let user configure some default attributes for tags created: - User should be able to define what the default point security should be - User should be able to decide if tags should be created as Poll or Advise
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Add a Trace Route feature to PI Ping interface

Add ping -i feature to the interface and allow for either the output of the ping time or destination in the PI tag. Case: This will allow for IT to monitor the network path taken in communication from one site to another. If the route has change...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

PI Interface for OPC DA bitmask plugin with float data type

PI Interface for OPC DA has a plugin called "Bitmask" to extract specific bits from regular OPC values that are of type Int (i.e VT_I2 / VT_I4 / VT_UI2) but other data types such as floats are not supported. It would be good to have Float data typ...
Guest 12 months ago in PI Interfaces / PI Interface for OPC DA 1 No status

Have the FTB Interface support multiple stop events for Unit Procedures

There are instances where a batch must be manipulated creating two Unit Released events in the event file. The desired behavior for the PI FactoryTalk Batch Interface would be for the second end time to overwrite the first end time when data is be...
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface not truncate the trailing "-#" index (e.g. UnitProcedureName-1) at the end of a Unit Procedure

Some FactoryTalk batch processes have overlapping Unit Procedures with trailing indexes. Because the trailing index is truncated it results in overlapping Unit Procedures with the same name which are then merged. The desired behavior would be for ...
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Have the FTB interface capture "Active Step Change Commencing" events as event frames

Some FactoryTalk batch processes require "Active Step Change Commencing" event to be part of the batch hierarchy however the PI Interface for Factory Talk Batch starts event frames only on [EVENT] = "System Message" or "State Change".
Guest 12 months ago in PI Interfaces / Batch Interfaces 0 No status

Add TCP option to PI UFL Interface

Currently the only two options are file reading or a serial interface. But what if you have ASCII data streaming from a TCP/telnet source? The configuration would be almost the same as serial - for the connection, rather than a serial port, just n...
John Alessio 6 months ago in PI Interfaces / PI Interface for UFL 0 No status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 2 years ago in PI Interfaces / PI Interface for OPC DA 1 No status

PI UFL ._OK file rename should be after parsing to avoid data loss during shutdowns

My understanding of UFL (confirmed by tech support) is that it will rename files to ._OK extension before loading lines into memory. This means that if the service is stopped (such as during an update) and it has not completely read into memory an...
Davin Ross over 1 year ago in PI Interfaces / PI Interface for UFL 0 No status

Improve collection of Event Viewer logs in PI Interface for Microsoft Windows Event Log

The PI Interface for Microsoft Windows Event Log can capture Event Viewer Logs. Some of the logs in sub-folders cannot be captured by the interface. This includes logs that store PI information, such as PI Vision with the log: OSIsoft-PIVisualizat...
Ted Birky about 1 year ago in PI Interfaces / Other Interfaces 0 No status