Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 383 of 4893

PI Connector for OPC UA Failed to populate Discovered Endpoints list

When pressing the Discover Available Endpoints button under the following condition , it failed to populate the Discovered Endpoints list because of 501 Error: a. NAT configured between PI Connector for OPC UA and OPC UA Server networks b. OPC UA ...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Make data source redundancy config more flexible

Some SCADA vendors are still only natively implementing OPC Classic so if one wants to use OPC UA, then a wrapper is needed. If that SCADA is configured in a redundant pair, it is not always true that the wrapper is aware of that or not aware of h...
sahilp about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Allow data sources and servers to be renamed

Currently, if you want to rename a data source, PI Data server, or PI Asset server, you must delete the one with the old name and create a new one with the new name, and redo all of the configuration. This is especially a pain for data sources, si...
Kenneth Barber about 2 years ago in PI Connectors / General 0 No status

Failover for PI Connector Relay

Although, the PI Connector Relay going down / not being available does not cause data loss since the connector data is buffered, if the source connector supports Failover, the relay becomes the only single point of failure in the data flow. Havi...
Gabriel Verreault about 2 years ago in PI Connectors / General 4 Declined

Create a connector for Profinet

Profinet is an industrial protocol which communicates over Ethernet. It offers a number of desirable features and functionalities which many of our customers find, or will find as the protocol becomes more widespread, very useful for collecting da...
Guest about 2 years ago in PI Connectors / New PI Connector Request 2 No status

Connector for GE HABConnect

Having a connector available for GE HABConnect rather than the interface would be useful to customers that are dealing with large amounts of data and make frequent changes to points on the GE side.  A connector that is capable of automaticall...
Guest about 2 years ago in PI Connectors / New PI Connector Request 0 No status

Need the WITSML connector to connect to Petrolink

As we know WITSML is a rather loose standard. A large integrated Oil and Gas Company would like for the WITSML connector to work with Petrolink https://www.petrolink.com/witsml/
Guest about 2 years ago in PI Connectors / New PI Connector Request 1 No status

PI Connector for Mitsubishi Electric MELSEC

Develop a connector for Mitsubishi Electric MELSEC
Guest about 2 years ago in PI Connectors / New PI Connector Request 1 No status

PI Connector for AMQP

Develop a connector for AMQP
Guest about 2 years ago in PI Connectors / New PI Connector Request 0 No status

Allow the data type of PI Points to be set manually with PI connector for OPCUA

[Background]We know that when use PI Connetor for OPCUA, the data type of the PI Point is synchronized with the OPC server settings. But we would like to set deferent one.e.x.) -Datatype of OPC Server tag : "String" -Data type wanted to be set for...
Guest 7 months ago in PI Connectors / PI Connector for OPC UA 0 No status