To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

PI Connectors

Showing 396 of 5209

Support Failover at the data source level

For PI Connector (1.x) that support failover like OPC UA, failover will only occur when all data sources get into a bad state. Failover should not have to be configure at the PI Connector node level, but for each data source. Use case 1: If 3 con...
Gabriel Verreault over 3 years ago in PI Connectors / General 1 Declined

Connectors should support a Send Rate parameter

Connectors need adapt to many different types of networks, in both configuration and quality (latency, etc.) of the data transfer. One of the features that interfaces had, but connectors still lack, is the ability to batch the values sent to PI an...
Guest over 3 years ago in PI Connectors / General 1 No status

Add support for HTTP/2 and HTTP/3 to the PI Data Collection Manager (PI DCM)

Currently, the PI Data Collection Manager's web GUI supports only HTTP/1.1. Please add support for HTTP/2 and HTTP/3 so that the web GUI will load faster.
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Add support for TLS 1.3 to the PI Data Collection Manager (PI DCM)

The highest version of TLS that the PI Data Collection Manager currently supports is 1.2. Please add support for TLS 1.3 to make the PI Data Collection Manager load faster and more securely.
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Add support for TLS 1.3 to the 1st-generation PI Connectors

The highest version of TLS that the 1st-generation PI Connectors currently support is 1.2. Please add support for TLS 1.3 to make the administration pages of the 1st-generation PI Connectors load faster and more securely.
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Drop support for TLS 1.0 & TLS 1.1 for the 1st-generation PI Connectors

For the administration pages of the 1st-generation PI Connectors, please drop support for TLS 1.0 & TLS 1.1. These have been known to be insecure protocols for a while now, are not supported by modern browsers, and have been superseded by TLS ...
Kenneth Barber over 3 years ago in PI Connectors / General 0 No status

Add a type casting function or operator

The INI files would be shorter and more readable if the PI Connector for UFL had a type casting function or operator. For example, if you are incrementing a Counter variable (type Int32) for each data line, and your tag names are Tag1, Tag2, etc....
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

Make a version of SkipFile() that stops processing the current file immediately

The current SkipFile() function tells the PI Connector for UFL to skip the remaining lines in the file, but the PI Connector for UFL will continue to execute the rest of the code in the "per message" section that the current line triggered. Pleas...
Kenneth Barber over 3 years ago in PI Connectors / PI Connector for UFL 0 No status

UFL Connector - sort input files by parameters other than name

Allow the UFL Connector to sort input files by parameters other than the name.  This will be useful in cases where file naming conventions will lead to large amounts of OOO data.
Guest over 3 years ago in PI Connectors / PI Connector for UFL 1 No status

Uninstall only the installed files & folders

It is standard for uninstallations to follow a procedure similar to this: Remove all files that were added during the installation. Then remove all folders that were added during the installation if they are currently empty. The PI Connector for ...