Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Connectors

Showing 386 of 4928

Allow options to alter the way the connector handles different qualities (bad, questionable)

At this time, the connector does not expose any way to alter the way data of different qualities (bad, good, questionable) is handled. The PI OPC Interface allows several different options with regards to “quality” such as "send only GOOD quality ...
Gabriel Verreault over 2 years ago in PI Connectors / PI Connector for OPC UA 1 Declined

Enable Relay/DCM to allow control over the data streams and destination PI Systems

Currently the Relay will send all data streams to all routed destination. This does not allow customers to have control over what data streams go to a specific destination. The only workaround is to have independent Connector/Relay pairs with spec...
Nico Cha over 2 years ago in PI Connectors / General 1 No status

Make the UFL Connector logic development/testing/debugging process less tedious

Deploying a UFL Connector solution requires a LOT of edits of the INI file as part of the development/testing/debugging process. After each INI file change and file save, the required procedure is as follows: 1. Click on the Data Source List link...
Mic Paluszak over 2 years ago in PI Connectors / PI Connector for UFL 0 Declined

Connector should rescan UA server, on a configureable basis, for new objects already defined in CSV file

It would be helpful if the UA Connector could rescan the UA server for new objects that have already been selected in the AvailableTypeDefinitions file and add them to the server on a configurable frequency.  We primarily use the UA Connector...
Steve Hampton over 2 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Allow specification of PI Point Attributes set by the PI Asset Connector for Emerson DeltaV 3.X

The PI Asset Connector for Emerson DeltaV 3.X sets PI Point Attributes either based on the values in the enterprise historian configuration file (EntHist.xml) or based on default values. It would be useful to have the option to adapt the PI Point...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 1 No status

Merge Two Tags or Copy Tag Data to a New Point

Sometimes, when dealing with APS, a new TAG is generated for an existing point. Data stops going to the old point. It would be nice if there was an easy way, within the gui (not manually dumping and importing) that we could take the values from on...
Guest over 2 years ago in PI Connectors / General 4 Declined

Remove or disable the PI Connector UFL function which puts "Excluded" into attributes

If the user has two different UFL flows working on same elements and attributes, one flow puts "Excluded" into the attributes created within the second one and vice versa. Giving the possibility to the user to disable this function would be a sma...
rodolforotti over 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

Connector (UFL) can read AF data structure

Right now it is a limitation because of the current functionality / design. In the future it would be nice if: - the connector can read the existing AF structure - update the existing AF structure - create elements / EF / attributes under existin...
Guest over 2 years ago in PI Connectors / PI Connector for UFL 1 Declined

Wonderware connector to store Bad/Questionable data from the WW Historian and flag as System Digital State (for example Bad Input, Bad etc) in the same Value PI Tag

As of the connector version 1.6.9.14, we can choose to store the Quality from the Historian in a separate Quality PI Tag (on top of the value PI Tag). Bad quality value is not being stored nor flagged in the Value PI Tag but this can be captured i...
Ee Sheing Lee over 1 year ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

DeltaV Smart Connector Update to OPC UA

The newest release of DeltaV has the capabilities of enabling an OPC UA server that could be used to transmit realtime date from DeltaV to the PI database. Right now, the interface between the two systems uses OPC DA. With DeltaV's plan to migrate...
Guest over 2 years ago in PI Connectors / Other specific PI Connector 3 No status