To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3269

Support user-defined data types in the PI Connector for EtherNet/IP

As an advanced user, I would like to be able to specify a user-defined data type for the array sent to the PI Connector for EtherNet/IP.  For example, if I have a 32-bit array composed of one INT and two SINTs, I would like to be able to conf...
Guest over 2 years ago in PI Connectors / PI Connector for Ethernet/IP 0 No status

Synchronize behavior between PI Connector for Cygnet and Cygnet enumeration value representation

The values stored in the “Table Entry” column in Cygnet TRS should match the “State” column in the PI Server Digital states table. This way end users are not confused why the trends in PI do not match the trends in Cygnet.
Guest over 2 years ago in PI Connectors / PI Connector for CygNet 0 No status

Further development of OMF

In OMF unfortunately more complex use cases are not possible Integration of Script functionally for generated elements from OMF are needed. Please insert an possibility or allow an other development method to use all AF functionality in case of ge...
photi24 over 2 years ago in PI Connectors / Other specific PI Connector 0 No status

View more detailed buffer queue statistics for PI Connector for OPC UA

I would like to get a more detailed view of the buffer queue for the PI Connector for OPC UA. In particular, I would like to be able to see the number of PI Events in the queue (not just the number of Tau Messages) and the amount of space filled i...
Jaedyn Larson over 2 years ago in PI Connectors / PI Connector for OPC UA 4 No status

Exclude Bad values from data collection in PI Connectors

PI connectors such as OPC UA, Wonderware and Cygnet send BAD values from the data source. We would like the option to filter these values out at the connector level such that they do not make the PI Data Archive.
Guest over 2 years ago in PI Connectors / General 0 No status

PI ML Web: Ability to create tours

Ability to configure tours in PI Manual Logger Web so that I can manage tours easily from a central web location.
Ryan McErlean over 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Bulk load of data via PI-ML

Within the PI-ML thick client it is possible to do a bulk load of data entry via an Excel Sheet. Within the web version of PI-ML this is not possible yet. We would like to see if it is possible to bulkloading of data also via PI-ML webversion.
peheuvel over 2 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Which attribute triggered analysis

I have an analysis that is event-triggered by multiple attributes. This analysis has the purpose of merging input attribute events with output tag, therefore I need to know which attribute triggered analysis to save only the newest event to outpu...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Function to retrieve Instrument tag

I want to have a function to retrieve a PI Tags Instrument tag in AF analytics
Hobbe over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 8 No status

Poly function should allow number attributes as coefficients

The current Poly function does not support attributes as coefficients, so we need to revert back to using Pow. This makes the Poly function of little additional benefit. We need to be able to use any numeric attribute as input for the Poly coeffi...
Guest over 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status