To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5193 of 5193

Calculated tags present value error

For calculated tags when being trended for more than ~12 hours time frame, the trend works fine except for the live present value, the calculation can be completely off. See attached screenshot for an example, where several tags are checked whethe...
AbdulRahman.Maskari 2 months ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status

Export data from the Display Sessions to a PI Point through an interface or performance counter

The Display sessions are very useful for daily monitoring. But having the option that allows us to save the data from this utility to a PI Point or attribute for later analysis would be useful for monitoring purposes
Guest 7 months ago in AVEVA™ PI Vision™ / Administration 0 No status

Improve performance

Please find a way to improve performance when needing to view 100+ days of data in dashboards. Potentially defaulting to 5mMID ( or less resolution) would help this
Guest 7 months ago in AVEVA™ PI Vision™ / User Experience 1 No status

PI AF SDK Linux Support

As we know there are 2 major competitor for cloud technologies that is Microsoft and Linux destros. If we want to use Linux docker image or PCF Linux image to connect AF SDK, we don't have any provision for this as of now because AF SDK does not s...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI AF SDK 5 No status

Trigger automatic recalculation for snapshot changed values

As for now, automatic recalculation is not triggered by changes on snapshot (KB01790), which means auto-recalculation does not work with snapshots values. The idea of it doing otherwise is to help users that mistakenly added a wrong new event to ...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 2 No status

Ability to change the configuration of the Asset drop-down using a URL parameter

I would like to be able to change the Asset drop-down from a navigation link in a PI Vision display ( in other words to change the configuration of the Context Switching for a display) so that I can reuse an existing display and point it to differ...
Guest over 3 years ago in AVEVA™ PI Vision™ / Navigation 5 No status

Allow configuration of trend legend position

Ability to move series legend around on trends (i.e. able to move beneath x-axis or right hand side or above trend, or freely overlay over trend)
Guest over 3 years ago in AVEVA™ PI Vision™ / Look & Feel / Styling 1 Declined

Add SOAP 1.2 support to the PI Interface for OPC XML-DA

The current version of the PI Interface for OPC XML-DA seems to only support SOAP 1.1. All recent OPC XML-DA servers are developed following SOAP 1.2 standards, meaning the PI interface will not connect. Please enhance the interface to also suppor...
Guest over 3 years ago in PI Interfaces / Other Interfaces 2 No status

Send only data that has changed.

When transferring data via satellite it is necessary to keep bandwidth usage to a bare minimum. Currently OMF must send all values regardless of whether they have changed or not. If it could send only the data parameters that have changed that wou...
Guest over 3 years ago in Developer Resources / Open Message Format (OMF) 6 Declined

Use a calculation in another calculation

Currently, you cannot use a calculated variable in another calculation on PI Vision. This complicates calculations because all operations must be done under one calculation.
Navern Moodley over 1 year ago in AVEVA™ PI Vision™ / Analytics / Calculations 0 No status