Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My subscriptions: PI Connectors

Showing 383 of 4901

PI APS Connector for GE XA21

The PI APS Connector for GE XA21 can not handle digital sets from GE XA21. This makes the Automatic Point Sync only semi automatic, You need to load the digital sets maually while Points are updated automatically. If the APS can transfer digital s...
ErikJansson about 2 years ago in PI Connectors / Other specific PI Connector 1 No status

IEC61850 - Ability to connect to a non-default port

The connector is currently unable to connect and collect data from MMS Servers using a port other than the default 102.Port selection should be part of the data source configuration
Gabriel Verreault about 2 years ago in PI Connectors / Other specific PI Connector 0 No status

Enable the option to not sync/overwrite pi point attributes for PI Connector GE e-terrahabitat after connector is started

As of version 1.1.1.42, by specifing tag under a given field node, this allows you to set any PI point attribute you want with an associated value. Furthermore, you can specify an associated key filter for that attribute. However, if we manually ...
Ee Sheing Lee about 2 years ago in PI Connectors / Other specific PI Connector 3 Declined

Update PI Connector for OPC UA to be interoperble with OCS & EDS

Update PI Connector for OPC UA to be interoperable with Edge Data Store (EDS) and OSIsoft Cloud Services (OCS).
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Add one more option for the "Incoming Timestamps"

Add one more option for the "Incoming Timestamps" Be able to use take the timestamp direkt from connector server/PC.
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Connector should create point in PI server irrespective of the source tag value field, whether blank or null

Connector should create point in PI server irrespective of it's value status in OPC UA server side, whether the source tag value field is blank or null, in either case, PI tag should be created for PI Connector for OPC UA 2.0.
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 1 No status

Enhance data collection manager compatibility

At the moment also the newest version of the DCM has many issues with different browsers. Buttons will not work, lists doesn't scale right and sliders hinding. Especialy the performance leak. We have 8 datasources with 500k values and 800 tags sel...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Put a PI Collective note directly on the Server List page

The PI Connector user guides mention "For a PI Data Archive collective, add each member of the collective to the PI Data servers list, not the collective itself." It would be useful to have this note directly on the Server List page.
Kenneth Barber about 2 years ago in PI Connectors / General 0 No status

"Connected" to invalid PI Data servers

If I add an invalid PI Data server in the Server List page, the PI Connector will say that it is connected to this data source. The status only becomes "Error" when the PI Connector tries to save data to this server. Please change this so that inv...
Kenneth Barber about 2 years ago in PI Connectors / General 1 No status

Warning when stopping a connector about potential consequences

Some connectors perform some kind of rediscovery of the data source upon start - Such as meta data or current values, etc. When stopping a connector from the UI, a warning should pop-up indicating potential consequences of doing so and what to exp...
Guest about 2 years ago in PI Connectors / General 1 No status