To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

My votes: PI Connectors

Showing 383 of 4906

Feature to turn off auto creation of PI Tags in PI Connector for UFL

Ability to turn off auto creation of PI tags - When data is sent via REST to a PI Connector for UFL service ,currently it looks for a PI Tag in the PI Server and if the PI Tag does not exist it creates a new PI Tag. It would be good if we could tu...
Guest about 2 years ago in PI Connectors / PI Connector for UFL 7 Declined

OPC UA: Set PI Tag Zero and Span Based on OPC UA Range

For OPC UA Analog Items, the OPC UA standard mandates an EURange property and an optional InstrumentRange property. These Range properties contain a Low and High field.The PI Connector for OPC UA should have an option to use either of these Ranges...
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 0 No status

Replicate AF Analyses with PI System Connector

I would like to have the option to replicate AF Analyses using PI System Connector with the option to mark the desired analyses for replication.
Guest about 2 years ago in PI Connectors / PI System Connector 1 Declined

Support Assigning Point Sources for Connectors

Connectors currently assign point sources; this is not user configurable.  In addition, all connector of like kind get the same point source.  This makes it difficult to determine which tags "belong" to which connector node.  Users ...
Brian Deslatte about 2 years ago in PI Connectors / General 2 Declined

Enable or Disable single DataSource

When a datasource is actually offline and we don't want the UFL connector to keep trying uploading or connecting to it and pollute the message log . The best option would be having the stop/start enable/disable and restart options for each dataso...
Andy about 2 years ago in PI Connectors / PI Connector for UFL 3 Declined

PI Connector for IEC 60870-5-104 writes 'No Data' or another SYSTEM digital state when connection to the Data Source is lost.

This connector is specially used to monitor the connection of the machines, but if there is a general network crash, and the connector losses the connection to the Datasource, it will stop sending data instead of sending something to alert of the ...
Guest about 2 years ago in PI Connectors / Other specific PI Connector 1 Declined

UFL Timezone Conversion

Supported timestamps are currently limited to Local or UTC timezones. Data sources may not be configurable to provide timestamps in supported formats. There currently exists no robust or simple way of converting between timezones using the UFL...
Guest about 2 years ago in PI Connectors / PI Connector for UFL 5 Declined

Enable setting tag attributes in UFL Connector

UFL Connector should have ways to set tag attributes. There should be way to set the default compression and exception settings and also other tag attributes like point and data security.
Guest about 2 years ago in PI Connectors / PI Connector for UFL 3 No status

Write event when data source is offline

As a PI admin I would like the OPC UA connector to write a value such as 'disconnected' when the data source is offline so that I know when the connector is unable to connect to the data source,
Guest about 2 years ago in PI Connectors / PI Connector for OPC UA 3 Declined

OPC UA Historical data recovery

The PI OPC UA connector can manage historical data recovery when connection is lost between the OPC UA server and the connector, but if the connection problem is between the OPC UA server and the data source on field, when connection is recovered ...
JavierCastane about 2 years ago in PI Connectors / PI Connector for OPC UA 4 No status