Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

PI Interfaces

Showing 229

PI Interface for GSE D/3 Compatibility Testing With Latest D/3 DBA Software

As of writing, the current version of the PI Interface for GSE D/3 (v 4.32.0.50) supports versions of D/3 up to 14.1-2 (consult the latest user guide for more details). It has not yet been tested for compatibility against more recent versions of N...
Guest over 2 years ago in PI Interfaces / Other Interfaces 2 No status

PI Interface for Foxboro I/A 70 Series should support Windows 10

On PI Interface for Foxboro I/A 70 series version 2.4.2.12, the supported operational System are Windows 2008 R2, Windows 7, Windows 8 and 8.1, Windows 2012 Server. Can we also test the interface against Windows 10, to included it as a supported OS?
Guest over 2 years ago in PI Interfaces / Other Interfaces 1 No status

Enhance the PI-ICU to include a rolling buffer regardless of connection to the PI Data Archive

During a Disaster Recovery test our team discovered that there will be up to 24 hours of data loss since our VM's are cloned once a day and the PI-ICU interfaces don't start caching data until the data archive has been disconnected. Essentially - ...
Guest almost 2 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 0 No status

Allow automatic interface restart based on Device Status

In some cases, such as when using a tunneller, the PI interface for OPC DA requires a restart to resume collecting data. A feature that allows an automatic restart of the service based on the value of the Device status Health tag would avoid human...
Alberto Tedesco over 1 year ago in PI Interfaces / PI Interface for OPC DA 1 No status

PI EMDVB - Set Procedure start time to match first Unit Procedure start time

Currently, when an operator adds a new batch to the DeltaV Batch List, that "creation" action starts a new EF Procedure. But the batch might sit in that list for a long time before the Unit actually starts processing it. This leads to a huge empty...
Guest 7 months ago in PI Interfaces / Batch Interfaces 0 No status

Batch interface to AF connection health monitoring tag

Having a health tag for batch interfaces which monitors the connection status between the interface and its corresponding AF server. This way, users can be informed if there are any issues with the interface creating event frames on AF.
Guest about 1 year ago in PI Interfaces / Batch Interfaces 0 No status

Option for PI Interface for UFL to purge read-only files

Create an option to allow the PI Interface for UFL to delete files with the read-only attribute.
Guest over 2 years ago in PI Interfaces / PI Interface for UFL 0 No status

Convert incoming string data to float and provide division all in the same tag instead of a PE

OPC server is outputting data with the currency data type (VT_CY) and it needs to be stored in the float type.  As per the OPCtoCSV document, the OPCtoCSV tool/OPC interface invokes VariantChangeType in order to convert this currency value to...
jagdish.konathala over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA, A&E historical recovery

We have seen that the primary OPC interface will be connected but we don't see data coming across since the OPC server itself seems to have a problem. Since the connection is still active we won't failover to the secondary. We have to leave Notifi...
Guest over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status

OPC DA interface to read data for advise and polled tags at startup

If digital tags are part of advise groups and the flag to write "Intf Shut" is enabled in the OPC DA interface, then digital tags can read "Intf Shut" for hours/days/weeks, if the value does not change after an interface restart (for example, 2 pu...
caffreys_col over 2 years ago in PI Interfaces / PI Interface for OPC DA 0 No status