To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 533 of 5193

PI OPCtoCSV tool to continue running and skip branches in error

The PI Interface for OPC DA is packaged with the PI OPCtoCSV tool which extracts all OPC Items. When the tool is run into error with certain branches, the tool will stop and disconnected from the OPC server/tunneller. For example: “GetItemProperti...
Ee Sheing Lee over 3 years ago in PI Interfaces / General 1 Declined

Allow diagnostic tags per failover node for batch interfaces

Batch interfaces should allow for diagnostic tags per failover node, just like UniInt based interfaces. Currently, there is no differentiation between the diagnostic tags for the primary failover node versus the backup failover node. The Location3...
Guest over 3 years ago in PI Interfaces / Batch Interfaces 0 No status

PI Interface for IEEE C37.118 support for Analog data Signed and Unsigned 16-bit Integers

The IEEE specification of the IEEE C37.118 protocol does not specify if analog data should be singed or unsigned for 16-bit integers. The currently the PI Interface for IEEE C37.118 represents these values as exclusively unsigned. Both types shoul...
Guest over 3 years ago in PI Interfaces / Other Interfaces 0 No status

Enhance WMI interface to verify that ACE Class Libraries are running

PI-ACE Manager looks at the PI-Module Database to see if the individual modules are running. The Class Library sub-processes updates the PI-MDB when it starts & stops. If the process dies, it does not always update the PI-MDB values. So, there...
Joe Staublin over 3 years ago in PI Interfaces / Other Interfaces 1 No status

EMDVB Data Type Enhancement

Please include option in the DeltaV EMDVB interface that can handle the timestamp format used with .evt files. Currently, if in the interface a trigger is used with a property, the timestamp format in the .evt file is retained, which cannot be sto...
Gary Moore 10 months ago in PI Interfaces / Batch Interfaces 0 No status

Restrict Batch interface from creating Event Frames using illegal characters

The PI Interface for Rockwell FactoryTalk Batch in processing evt files used a hexadecimal character of 1f in the generation of an event frame. This results in an error when attempting to export the event frame in an xml output.
Nathan Skitt 10 months ago in PI Interfaces / Batch Interfaces 3 No status

Public PI Web API Endpoint (for health checks)

Currently, all endpoints of the PI Web API are access protected. When using the PI Web API with a load balancer (namely with managed load balancers from AWS/Azure), the health check endpoint for the servers must be configured to accept both 200 &a...
Tyler Engelhardt about 2 years ago in AVEVA™ PI System Access (PSA) / PI Web API 1 No status

PI OLEDB Enterprise access to AF Tables

Allow PI OLEDB Enterprise access to AF Tables.  The current workaround is to have the table live on a SQL database and then link to them from AF.
MAMEDINA over 3 years ago in AVEVA™ PI System Access (PSA) / PI OLEDB Enterprise 2 Declined

Allow configuration of the PI OPC DA Server's ProgID

The ProgID of the 2015 PI OPC DA Server is OSISoft.OPCDA2.DA.1, while the ProgID of the 2010 PI OPC DA Server is OPC.DA.1. Existing client tools that pointed to the 2010 PI OPC DA server will need to be reconfigured to point to the new ProgID aft...
Guest over 3 years ago in AVEVA™ PI System Access (PSA) / PI OPC DA & HDA Servers 3 Declined

Add support for nested SELECT statements in PI SQL (RTQP)

The current version of PI DAS (RTQP Engine) does not support nested SELECT statements. This is a rather dire oversight, given that the older PI OLEDB Enterprise query engine does support nested SELECT statements. A very useful application of nes...