Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

AVEVA™ PI Server

Showing 1347

Stop EF after given time

Als a PI admin I want to have the option to stop/end a EF after a given time. This helps to trigger and track onetime events as for example taking a reactor sample.
meierke1 over 3 years ago in AVEVA™ PI Server / Event Frames (EF) 3 No status

Allow additional authentication types for web service delivery endpoints in PI Notifications

Allow for additional authentication types to be added for web service delivery endpoints. Currently, the only available options are Windows, Anonymous, and Basic.
Guest over 3 years ago in AVEVA™ PI Server / Notifications 7 No status

Row/variable information to AF Analysis errors

When we built complex analysis and evaluate in PI System explorer we get general error messages without any information where the error occurs. This makes troubleshooting painful. Adding row/variable information would already help a lot!
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

if then else in Analysis still checking/executing both parts

If then else clauses are often used for input filtering for our analysis in AF. We often face the issue that analysis cause errors although the part which should not be executed according to the condition is causing errors.Example: "if BadVal('att...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Ability to embed substitution parameters

I would like the ability to embed a substitution parameter within another substitution parameter. For example, in the following Configuration String: \\%Server%\%@||TagName% I would like to replace with a substitution parameter
Guest over 3 years ago in AVEVA™ PI Server / Asset Framework (AF) 3 No status

Change default setting for new analysis templates enabling from True to False

When an analysis template is added or new analysis are created with PI Builder the default option is to "enable analyses when created from template" = True. This should be changed to false with an opt-in for automatic enabling. Users easily forget...
PhilippEven about 1 year ago in AVEVA™ PI Server / Asset Framework (AF) 1 No status

Add a PI Analysis Service performance counter to track stopped analyses

The PI Analysis Service has performance counters to track the number of running analyses and the number of suspended analyses, but there is not one that tracks the number of stopped analyses. Currently, the only way to monitor how many AF analyses...
Bethany Jewett 9 months ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

PI Builder security alignement

We have some user that are able to edit some fields in AF using System explorer but they cannot do it using PI Builder (that require database access). Please align PI Builder access and PI System explorer because the actual situation is a nonsense
dgenet 11 months ago in AVEVA™ PI Server / Security 0 No status

Remove installation kits' dependency on write permission to root C:\.

Some organizations do not provide admin accounts with write permission to the root C:\ directory. The install kits of most PI products copy the setup.ini to C:\pisetup.ini, and then write the logs to C:\ before moving them to %pipc%\dat, both of w...
Guest over 3 years ago in AVEVA™ PI Server / Installation 4 No status

PI Auditviewer Usability Enhancements

From a pharma/biotech user perspective, I am finding that the PI Auditviewer application is difficult to use and conduct an investigation with over an extended time period.  I believe the application needs an overhaul to allow for, at minimum...