To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 3539

Make the connector a BACnet Device (get a BTL listing)

Some devices can only send COV notifications to other BACnet devices. Since the Connector is not a device and does not respond to who-is messages (and does not listen on port 47808), the connector is unable to utilize COV subscriptions for these d...
Paul Kim over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Suppress the creation of "Status Flag" PI Points

The end-user would like to suppress the creation of the "Status Flag" PI Points, as they wish to keep their point count to a minimum due to the license-enforced point limit.
Guest over 3 years ago in PI Connectors / PI Connector for BACnet 0 No status

Validate credentials before running connector

Need a way to easily confirm that the credentials are correct before I try and run the connector.  Would like to see any errors surfaced via the web page so I can troubleshoot.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

PI Connector for Wonderware Historian should automatically create digital PI Tags

Currently the connector creates all discrete Wonderware tags with a Point Type of Int32. As a PI System Administrator, I would like the connector to have the option to create these tags as digitals and automatically create their respective Digital...
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

The PI Connector for Wonderware Historian should automatically populate the point attributes Zero and Span when creating PI Tags.

As a PI System Admin, I would like the PI Connector for Wonderware Historian to automatically populate the point attributes Zero and Span when creating PI Tags so that these attributes do not have to be manually edited after the tags are created.
Guest over 3 years ago in PI Connectors / PI Connector for Wonderware Historian 0 No status

Setting of parameters k and w for IEC 60870-5-104

Parameters k (Maximum number of outstanding I format APDUs) and w, cannot be adjusted, while vendors recommend customers to set it to k=12 and w=8
Guest over 3 years ago in PI Connectors / Other specific PI Connector 1 No status

X509 User Token Policy

Allow future releases of the OPC UA Connector to support user authentication via certificate or IssuedToken instead of only through user/password or anonymous connection.
Guest over 3 years ago in PI Connectors / PI Connector for OPC UA 2 No status

Include a "Disable" option for Table Connections

Linked Tables can cause bad behaviors (freezes; attributes waiting for values) in PI System Explorer when the password supplied is no longer valid. The solution is to update the password, or delete the Table Connection if the new password isn't av...
Guest over 3 years ago in AVEVA™ PI Server / General 0 No status

PI Manual Logger App

Business feels its easier to use PI ML as an app rather than webpage.
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 0 No status

Add the ability to only allow data entry users to change the date, but not time, for Manual Logger Web tours

Customer wants to have an option to enter all tags at midnight, without having the user to select the time, therefore user only select the data and the time default to midnight (they can modify if required but it should always default to midnight).
Guest over 3 years ago in AVEVA™ PI Vision™ / Manual Data Entry / PI Manual Logger 1 No status