Skip to Main Content
AVEVA™ PI System™ Feedback Portal

Welcome to our feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 1629

amqp

Support AMQP over Websockets to allow streaming to Azure IoT Hub using only HTTPS/port 443 to be more compatible with firewalls and proxy servers.
Steve Boyko over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Allow option to include SYSTEM Digital State in value column

Currently, whenever there is a SYSTEM Digital State written to a PI Point attribute, the PI Integrator for BA will output a null and to be able to publish the state value, an additional data column for status needs to be added. It would be nice ...
Guest over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Streaming views without time delay

Messages sent to Kafka targets from streaming views are sent in batches, which causes unwanted delay for the first created messages in the batch. Our users need the streaming data without delays. Send the messages as they are created, without time...
StefanFors over 3 years ago in PI Integrators / AVEVA™ PI Integrator for Business Analytics 0 No status

Write Event Frame analysis outputs to attributes at the child level

We often write outputs at close to event frame attributes that reference a PI Point attribute on the referenced element. The analysis will not write to an EF attribute if it points to a referenced element attribute at the child level. In the examp...
Gregory Malek over 1 year ago in AVEVA™ PI Server / Event Frames (EF) 0 No status

add-on for dataquality

Data scientists are 70% of their time busy with cleaning data. In the pi system, we can se lo and hi limits, but dataquality is more than that. It's also about consistent and continuous datarate, strange sensor signals,...Within Pi, this is still ...
Guest almost 2 years ago in AVEVA™ PI Server / Data Archive 0 No status

Password Protection For AF Databases

For AF databases we want to go beyond the AF security configuration and add password protection layer for databases.
Mohammed Qasim Asghar almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Ability to disable recalculation at the Database level in AF

Currently backfilling and recalculation are only enabled and disabled at the global and element level. There are instances where users of Asset Analytics, particularly when it comes to event frames, experience automatic recalculation upon a servic...
zachary cmelak almost 2 years ago in AVEVA™ PI Server / Asset Framework (AF) 0 No status

Refrain from creating PI Points when AF Analytics is doing an expensive calcultion

If it can be known that the Analytics service is busy with an expensive calculation, the Data Archive should pause on creating PI Points, as this is also an expensive operation and may interfere with the calculation completion.
Laurie Dieffenbach about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status

Enable the compatibility of PI Builder with Microsoft 365/O365

With the existing versions, the PI Builder plugin doesn't work with O365 in its full capability. It would be great to have the compatibility setup from PI Builder plugin with MS365.
Guest about 2 years ago in AVEVA™ PI Server / PI Builder 0 No status

Add a performance counter which can measure if Event frame reconciliation is performed correctly

Currently we only can tell an event frame reconciliation is performed by the green check after auto calculation, and it is not very easy to monitor. Since event frame usually use for alarms to operators. Accuracy is very important. We try to avoid...
Guest about 2 years ago in AVEVA™ PI Server / Analytics & Calculations 0 No status