To start, take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas and comments are visible to all other users.


This page is for feedback specifically for AVEVA PI System. For links to our other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 5200

PI Integrator does not consistently sample the data at 2:00 AM during the DST change.

If we configure a view to sample an average data once a day at 2:00 AM, the sampling time will shift by one hour after the DST change. This impacts our calculations because the timestamps are recorded at 1:00 AM after the DST change. We want the d...
Ahmad Fitri BIN ROSLAN about 1 month ago in PI Integrators / General 0 No status

Add configurable defaults for PI Point "Pointsecurity" and "Datasecurity"

Read access to the PIPOINT table is required for most identities. Pointsecurity and Datasecurity currently use the settings on the PIPOINT table as the default. New points will generally give read access to most identities because of these default...
Guest over 3 years ago in AVEVA™ PI Server / Security 2 No status

Percentile function

As a user of analyses, I would like to have a Percentile function so that I can filter out atypical events when doing summary calls. The function would look like this: Percentile('attribute', 'timerange', value). This is related to enhancement req...
Guest over 3 years ago in AVEVA™ PI Server / Analytics & Calculations 4 No status

View Annotations via PI Vision

Ability to see annotations, such as those from Manual Logger, in Pi Vision.
Guest over 3 years ago in AVEVA™ PI Vision™ / Symbols 4 No status

PI Adapter for OPC UA Array Support

As a PI System Administrator, I would like for the PI Adapter for OPC UA to support array data types from the OPC UA Server. A large amount of our data may be contained within arrays on our OPC UA Server, so we would not currently be able to colle...
Guest over 3 years ago in AVEVA™ Adapters / AVEVA Adapter for OPC UA 12 No status

Delete a list of PI Vision Displays

I can use PI Vision Admin page to get statistics of display usage. After analysing these statistics, I would like to be able to delete the unused displays in bulk. I have thousands of unused displays and selecting them one-by-one in PI Vision Disp...
Muhammed Ali Otmanli 4 months ago in AVEVA™ PI Vision™ / Display Management / Displays Page 1 No status

PI Vision must not allow users to trend the string tags

PI Vision must not allow users to trend the string tags. This is confusing from the end users perspective as the PI Vision is assigning random numbers while plotting the string values. Logically, string values are not trend able. End users (read o...
Navaneethakrishnan 5 months ago in AVEVA™ PI Vision™ / User Experience 1 No status

Control which PI/AF servers each data source sends data to.

Right now, for one instance of the connector, all configured data sources will send data to all configured PI Data Archives and PI AF Servers. It is all or nothing. Due to the fact that you cannot have multiple instances of the same connector on a...
Guest over 3 years ago in PI Connectors / General 0 No status

Provide coding capabilities just like VBA in processbook

Provide coding capabilities just like VBA in processbook
Guest over 3 years ago in AVEVA™ PI Vision™ / Extensibility 1 No status

Migrate the PI ICU settings away from the PI Module Database

PI ICU settings are currently the main reason why the PI Module Database continues to live on even the most up-to-date PI systems. Please consider migrating the PI ICU settings from the PI Module Database to the PI Asset Framework or a separate fi...
Kenneth Barber over 3 years ago in PI Interfaces / PI Interface Configuration Utility (PI ICU) 5 No status